Skip to main content Skip to search Skip to main navigation
Please note our information regarding customs and duties. Delivery available from £140.
Average rating with

Average rating of 4.9 out of 5 stars

(4.91/5.00) calculated out of 2920 reviews

Concealed Mixer Valve Round

  • Made of solid brass
  • High-quality chrome finish
  • Durable ceramic cartridge
  • For a single user
  • Minimum installation depth 56mm
  • Maximum installation depth 80mm

Retro/Nostalgic Shower Rod

  • Completely made of solid brass
  • High-quality chrome finish
  • Adjustable holder angle (ball joint)
  • Drilling hole distance 61.5cm ±1cm
  • Ø Rosettes 5 cm

Retro/Nostalgic Hand Shower

  • Made of solid brass
  • Chrome-plated
  • Ceramic handle with border
  • 1 function
  • 20 cm long
  • Head Ø 7.2 cm
  • 1/2" connection
  • Compatible with all standard shower hoses

Wall Connection Elbow

  • Nostalgic design
  • Made of solid brass
  • High-quality chrome finish
  • Backflow prevention compliant with DIN EN 1717
  • 1/2" thread

Shower Hose Length 160 cm

  • The dual-sided 1/2" swivel cones prevent twisting of the hose. <\/strong><\/li>
  • Made of stainless steel, high-gloss polished
Double winding (overlapping) for high tensile strength Kink-resistant, durable, flexible Swivel cones made of solid brass, high-quality chrome-plated Certified: KTW recommendation, EN 1113, NF077 Made in Germany

Shipping

  • Shipping weight: 3.49 Kg
  • Shipping method: Paket

Product Safety Regulation

Manufacturer information:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 08.04.2026, 18:41:41

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Weitere Kundenbilder zu im Set enthaltenen Produkten

PaulGurkes Concealed Single-Lever Mixer with Installation Box

PGHPUM2

£81*

PaulGurkes Retro Nostalgia Shower Rail

PGHPR7

£87*

PaulGurkes Retro Nostalgia Hand Shower with Ceramic Handle in Brass

PG0316

£37*

PaulGurkes Wall Connection Arch Nostalgia Retro

PGHPWABR

£26*

PaulGurkes Stainless Steel Shower Hose 160cm with Swivel Connectors

PGdoubleAgraff160

£16*

Documents of the products included in the set

PGHPUM2

[pdf] Analysebericht-PGHPUM1-2
Analysis Report Introduction
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Report Information
Bericht-Nr.: #2017-731Report No.: #2017-731
Herstellernummer: PGHPUM1 / PGHPUM2Manufacturer number: PGHPUM1 / PGHPUM2
Material Composition
Kupfer Cu 57,799 ± 0,486 57,000 60,000Copper Cu 57.799 ± 0.486 57.000 60.000
Zink Zn 39,685 ± 0,435 37,000 41,500Zinc Zn 39.685 ± 0.435 37.000 41.500
Blei Pb 1,975 ± 0,150 1,600 2,200Lead Pb 1.975 ± 0.150 1.600 2.200
Eisen Fe 0,299 ± 0,051 0,000 0,300Iron Fe 0.299 ± 0.051 0.000 0.300
Nickel Ni 0,036 ± 0,032 0,000 0,100Nickel Ni 0.036 ± 0.032 0.000 0.100
Zinn Sn 0,000 ± 0,108 0,000 0,300Tin Sn 0.000 ± 0.108 0.000 0.300
Aluminium Al 0,000 0,050Aluminum Al 0.000 0.050
Suitability Confirmation
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Environment Agency (Umweltbundesamt) regarding the "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the German Environment Agency, the material meets the DIN 50930-6 standard, which provides statements regarding corrosion resistance.
Material Specification
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Signatures
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, 3. Oktober 2017Hildesheim, October 3, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Engineering & Quality Management
Umweltbundesamt Reference
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).German Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 03.04.2017).
[pdf] PGHPUM2-v1.1
Components
Nr. Komponente Anzahl 1 Griff 1 2 Blende 1 3 Box 1 Zertifikat unter: 4 1 www.paulgurkesshop.de 5 Anleitung 1No. Component Quantity 1 Handle 1 2 Cover plate 1 3 Box 1 Certificate under: 4 1 www.paulgurkesshop.de 5 Instruction 1
Installation Preparation
Installationsvorbereitung • Verwenden Sie die vorderen Befestigungspunkte um die Box in eine Holz oder Ständerwand zu installieren. • Verwenden Sie die hinteren Befestigungspunkte um die Box in einer massiven Wand zu verankern. • Überprüfen Sie ob Sie genügend Platz für die Unterputz-Box haben. • Spülen Sie die Leitung, bevor Sie die Armatur montieren.Installation Preparation • Use the front mounting points to install the box in a wood or stud wall. • Use the rear mounting points to anchor the box in a solid wall. • Check that you have enough space for the concealed box. • Flush the pipe before installing the fitting.
Installation Steps
Installationsschritte • Überprüfen Sie die Einbautiefe (vergessen Sie nicht den Putz und die Fliesen!) • Schließen Sie links Warmwasser und rechts Kaltwasser an. • Schließen Sie den Verbraucher oben an. • Überprüfen Sie die Montage auf Dichtheit. • Putzen Sie die Montage ein und dichten Sie die Armatur mit einer geeigneten Dichtmanschette im Verbund ab. • Fliesen Sie die Wand. • Schneiden Sie den überstehenden Kunststoff der Box ab und montieren Sie Sichtteile.Installation Steps • Check the installation depth (do not forget the plaster and tiles!) • Connect hot water on the left and cold water on the right. • Connect the consumer at the top. • Check the assembly for leaks. • Plaster the assembly and seal the fitting with a suitable sealing sleeve in the composite system. • Tile the wall. • Cut off the protruding plastic of the box and mount visible parts.
Water Regulation
Wasser regeln • Regeln Sie die Intensität indem Sie den Griff anwinkeln. Durch Bewegen des Griffs nach links (warm) und rechts (kalt) regeln Sie die Temperatur.Water regulation • Regulate the intensity by angling the handle. Adjust the temperature by moving the handle to the left (warm) and right (cold).
Important
WICHTIG • Das Loch in der Fliese muss exakt die Maße der Box haben, sonst verdeckt die Blende nicht den Ausschnitt der Fliese.IMPORTANT • The hole in the tile must exactly match the dimensions of the box, otherwise the cover plate will not cover the cut-out in the tile.
Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.We reserve the right to make updates, changes or additions to the information and data provided.

PGHPWABR

[pdf] Analysebericht-PGHPWABR
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Bericht-Nr.Report No.:
HerstellernummerManufacturer Number:
EANEAN:
KupferCopper
ZinkZinc
BleiLead
EisenIron
ZinnTin
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The evidence of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency regarding the 'Evaluation basis for metallic materials in contact with drinking water' - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information regarding corrosion resistance.
WerkstoffMaterial: CW617N (CuZn40Pb2)
Olaf Manusch, GeschäftsführerOlaf Manusch, Managing Director
Hildesheim, Montag, 3. April 2017Hildesheim, Monday, April 3, 2017
Marc Manusch, Leitung Technik & QualitätswesenMarc Manusch, Head of Technology & Quality Assurance
UmweltbundesamtFederal Environment Agency: 'Evaluation basis for metallic materials in contact with drinking water', (accessed on 04/03/2017).
Analysis Reports - PGHPWABR - Version 1
Manufacturer Information
Herstellerinformation
PaulGurkes GmbH
Klingenbergstr. 12
31139 Hildesheim
Analysis Report
Analysenbericht
XL2-99147
Measurement No.: 677
Mode: Alloys
Measurement Duration: 3.1s
Time: 29.09.2017 17:33:44
Material Information
Werkstoffinformation
Manufacturer Number: pghpwabr - body
Material Suggestion: CW617N_CuZn40Pb2
User Login: Marc Manusch
Element Analysis
Elementanalyse
Element: Copper Cu | %: 57.954 | ±2σ: ±1.050 | Min: 57.000 | Max: 60.000
Element: Zinc Zn | %: 39.749 | ±2σ: ±0.929 | Min: 37.000 | Max: 41.500
Element: Lead Pb | %: 1.944 | ±2σ: ±0.316 | Min: 1.600 | Max: 2.200
Element: Iron Fe | %: 0.329 | ±2σ: ±0.111 | Min: 0.000 | Max: 0.300
Element: Tin Sn | %: 0.000 | ±2σ: ±0.249 | Min: 0.000 | Max: 0.300
Element: Nickel Ni | %: 0.000 | ±2σ: ±0.091 | Min: 0.000 | Max: 0.100
Element: Aluminium Al | Min: 0.000 | Max: 0.050
Notes
Hinweise
* Please enter text here. *
Analysis Reports - PGHPWABR - Version 1
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. The sample was tested using X-ray fluorescence analysis and yielded the following measurement result. Evidence of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been established.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. The tested material complies with the requirements of the Federal Environmental Agency (UBA) regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environmental Agency, the material meets the DIN 50930-6 standard, which establishes requirements for corrosion resistance.
Material
CW617N (CuZn40Pb2) CW617N (CuZn40Pb2)
Product Information
Bericht-Nr.: #2017-677 Report No.: #2017-677
Herstellernummer: PGHPWABR Manufacturer No.: PGHPWABR
EAN: 4250914808797 EAN: 4250914808797
Measurement Data
Messung Nr.: 677 Measurement No.: 677
Modus: Legierungen Mode: Alloys
Messdauer: 3,1s Measurement Duration: 3.1s
Zeit: 29.09.2017 17:33:44 Time: 29.09.2017 17:33:44
Werkstoffvorschlag: CW617N_CuZn40Pb2 Material Suggestion: CW617N_CuZn40Pb2
Element Analysis
Kupfer Cu: 57,954 ± 1,050 (Min: 57,000, Max: 60,000) Copper Cu: 57.954 ± 1.050 (Min: 57.000, Max: 60.000)
Zink Zn: 39,749 ± 0,929 (Min: 37,000, Max: 41,500) Zinc Zn: 39.749 ± 0.929 (Min: 37.000, Max: 41.500)
Blei Pb: 1,944 ± 0,316 (Min: 1,600, Max: 2,200) Lead Pb: 1.944 ± 0.316 (Min: 1.600, Max: 2.200)
Eisen Fe: 0,329 ± 0,111 (Min: 0,000, Max: 0,300) Iron Fe: 0.329 ± 0.111 (Min: 0.000, Max: 0.300)
Zinn Sn: 0,000 ± 0,249 (Min: 0,000, Max: 0,300) Tin Sn: 0.000 ± 0.249 (Min: 0.000, Max: 0.300)
Nickel Ni: 0,000 ± 0,091 (Min: 0,000, Max: 0,100) Nickel Ni: 0.000 ± 0.091 (Min: 0.000, Max: 0.100)
Aluminium Al: 0,000 (Max: 0,050) Aluminum Al: 0.000 (Max: 0.050)
Signatories
Olaf Manusch - Geschäftsführer Olaf Manusch - Managing Director
Marc Manusch - Leitung Technik & Qualitätswesen Marc Manusch - Head of Engineering & Quality Management
Company
PaulGurkes GmbH PaulGurkes GmbH
Klingenbergstr. 12 Klingenbergstr. 12
31139 Hildesheim 31139 Hildesheim
Date
Hildesheim, Montag, 3. April 2017 Hildesheim, Monday, April 3, 2017

[PDF] Allgemeine Pflegehinweise

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Loading...

Loading 3D model...

Mouse: Rotate | Scroll: Zoom | Right-click: Pan Finger: Rotate | Pinch: Zoom | Two fingers: Pan