PaulGurkes Square Series Faucet Set
Prices excl. VAT plus shipping costs
Dispatch by 10 September 2026 — Delivery time : 4-5 Days
Matching pieces
Will it fit your situation?
- Shipping weight7,6 kg
Reviews
2,969 verified shop reviews. This product has no review of its own yet — share your experience and help others plan their bathroom. We verify all reviews for authenticity.
Vanity Faucet
- Square design faucet
- Made of solid brass
- High-quality chrome finish
- Equipped with a premium ceramic cartridge tested and approved according to KTW guidelines (drinking water regulations)
- Durable aerator
- Flexible hoses 3/8"
- Provision for pop-up waste assembly included
Bathtub Faucet
- Made of solid brass
- Quality chrome finish
- High-quality ceramic cartridge tested and approved according to KTW guidelines (drinking water regulations)
- Durable aerator
- With diverter for hand showers
- Backflow prevention compliant with DIN EN 1717
- 1/2" connections
- Center distance 15cm±2cm
Shower Faucet
- Made of solid brass
- High-quality chrome finish
- Equipped with a premium ceramic cartridge tested and approved according to KTW guidelines (drinking water regulations)
- 1/2" connections
- Center distance 15cm±2cm
- With backflow preventer
Shipping
- Shipping weight: 7.6 Kg
- Shipping method: Paket
Product Safety Regulation
Manufacturer information:
Name des Herstellers: PaulGurkes GmbH
Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland
Elektronische Adresse: info@paulgurkesshop.de
Letztes Update: 08.09.2026, 22:08:09
Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.
Weitere Kundenbilder zu im Set enthaltenen Produkten
Documents of the products included in the set
PGVM16
| Analysis Report | |
| Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. | The sample was tested using X-ray fluorescence analysis and yielded the following measurement result. |
| Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. | The proof of suitability for drinking water installations in accordance with the Drinking Water Ordinance (TrinkwV 2001) is hereby established. |
| Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. | The tested material complies with the requirements of the Federal Environmental Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. |
| Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. | According to the Federal Environmental Agency, the material meets the DIN 50930-6 standard, which sets out statements regarding corrosion resistance. |
| Material | |
| CW617N (CuZn40Pb2) | CW617N (CuZn40Pb2) |
| Report Information | |
| Bericht-Nr.: #2017-429 | Report No.: #2017-429 |
| Herstellernummer: PGVM16 | Manufacturer No.: PGVM16 |
| EAN: 4250914800241 | EAN: 4250914800241 |
| Datum: Hildesheim, Montag, 3. Juli 2017 | Date: Hildesheim, Monday, July 3, 2017 |
| Signatories | |
| Olaf Manusch - Geschäftsführer | Olaf Manusch - Managing Director |
| Marc Manusch - Leitung Technik & Qualitätswesen | Marc Manusch - Head of Engineering & Quality Management |
| Company | |
| PaulGurkes GmbH | PaulGurkes GmbH |
| Klingenbergstr.12 | Klingenbergstr.12 |
| 31139 Hildesheim | 31139 Hildesheim |
| Analysis Report XL2-99147 | |
| Messung Nr.: 429 | Measurement No.: 429 |
| Modus: Legierungen | Mode: Alloys |
| Messdauer: 9,0s | Measurement Duration: 9.0s |
| Zeit: 03.07.2017 09:01:03 | Time: 07/03/2017 09:01:03 |
| Herstellernummer: pgvm16x | Manufacturer No.: pgvm16x |
| User Login: Marc Manusch | User Login: Marc Manusch |
| Werkstoffvorschlag: CW617N_CuZn40Pb2 | Material Suggestion: CW617N_CuZn40Pb2 |
| Element Analysis | |
| Kupfer Cu: 59,178% ± 0,709 (Min: 57,000 Max: 60,000) | Copper Cu: 59.178% ± 0.709 (Min: 57.000 Max: 60.000) |
| Zink Zn: 38,620% ± 0,611 (Min: 37,000 Max: 41,500) | Zinc Zn: 38.620% ± 0.611 (Min: 37.000 Max: 41.500) |
| Blei Pb: 1,964% ± 0,208 (Min: 1,600 Max: 2,200) | Lead Pb: 1.964% ± 0.208 (Min: 1.600 Max: 2.200) |
| Eisen Fe: 0,153% ± 0,057 (Min: 0,000 Max: 0,300) | Iron Fe: 0.153% ± 0.057 (Min: 0.000 Max: 0.300) |
| Zinn Sn: 0,000% ± 0,261 (Min: 0,000 Max: 0,300) | Tin Sn: 0.000% ± 0.261 (Min: 0.000 Max: 0.300) |
| Nickel Ni: 0,000% ± 0,067 (Min: 0,000 Max: 0,100) | Nickel Ni: 0.000% ± 0.067 (Min: 0.000 Max: 0.100) |
| Aluminium Al: 0,000 (Min: 0,050) | Aluminum Al: 0.000 (Min: 0.050) |
PGVM33
Analysis Report
| |||||||||
Report Details
| |||||||||
Element Composition
| |||||||||
Suitability for Drinking Water Installations
| |||||||||
Material Designation
| |||||||||
Signatures
| |||||||||
| Analysis Report | |
| Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. | The sample was tested using X-ray fluorescence analysis and provided the following measurement result. Proof of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus established. |
| Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. | The tested material complies with the requirements of the German Federal Environment Agency regarding "Assessment basis for metallic materials in contact with drinking water" - UBA positive list. According to the German Federal Environment Agency, the material meets the DIN 50930-6 standard, which establishes requirements regarding corrosion resistance. |
| Material | |
| CW617N (CuZn40Pb2) | CW617N (CuZn40Pb2) |
| Product Information | |
| Bericht-Nr.: #2017-374 | Report No.: #2017-374 |
| Herstellernummer: PGVM33 | Manufacturer Number: PGVM33 |
| EAN: 4250914802184 | EAN: 4250914802184 |
| Measurement Results | |
| Messung Nr.: 374 | Measurement No.: 374 |
| Modus: Legierungen | Mode: Alloys |
| Messdauer: 11,0s | Measurement Duration: 11.0s |
| Zeit: 03.04.2017 16:03:28 | Time: 03.04.2017 16:03:28 |
| User Login: Marc Manusch | User Login: Marc Manusch |
| Element Analysis | |
| Element | Element |
| % | % |
| ± | ± |
| Min | Min |
| Max | Max |
| Kupfer Cu | Copper Cu |
| 60,228 | 60.228 |
| ±0,981 | ±0.981 |
PGVM23
Components
| |||
Technical Data Ceramic Cartridge
| |||
Operation
| |||
Installation Steps
| |||
Cleaning & Maintenance
| |||
PaulGurkes Quality
| |||
Disclaimer
| |||
Analysis Report Header
| |||||||||||||||||||||||||||||||||||||||||||
Report Details
| |||||||||||||||||||||||||||||||||||||||||||
Material Composition Table
| |||||||||||||||||||||||||||||||||||||||||||
Compliance Statements
| |||||||||||||||||||||||||||||||||||||||||||
Material Designation
| |||||||||||||||||||||||||||||||||||||||||||
Signatures and Date
| |||||||||||||||||||||||||||||||||||||||||||
Source Information
| |||||||||||||||||||||||||||||||||||||||||||
| Analysis Report | |
| Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. | The sample was tested using X-ray fluorescence analysis and provided the following measurement result. The suitability for drinking water installations in accordance with the Drinking Water Ordinance (TrinkwV 2001) is hereby proven. The tested material meets the requirements of the Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material complies with the standard DIN 50930-6, which provides statements regarding corrosion resistance. |
| Material and Report | |
| Werkstoff: CW617N (CuZn40Pb2) | Material: CW617N (CuZn40Pb2) |
| Bericht-Nr.: #2017-347 | Report No.: #2017-347 |
| Herstellernummer: PGVM23 | Manufacturer Number: PGVM23 |
| EAN: 4250914806175 | EAN: 4250914806175 |
| Measurement Results | |
| Analysenbericht XL2-99147 | Analysis Report XL2-99147 |
| Messung Nr.: 363 | Measurement No.: 363 |
| Modus: Legierungen | Mode: Alloys |
| Messdauer: 10,6s | Measurement Duration: 10.6s |
| Zeit: 03.04.2017 15:46:54 | Time: 03.04.2017 15:46:54 |
| Herstellernummer: pgvm23 | Manufacturer Number: pgvm23 |
| Werkstoffvorschlag: CW617N_CuZn40Pb2 | Material Suggestion: CW617N_CuZn40Pb2 |
| Element Analysis | |
| Element | Element |
| % | % |
| ± 2σ | ± 2σ |
| Min | Min |
| Max | Max |