Skip to main content Skip to search Skip to main navigation
Please note our information regarding customs and duties. Delivery available from £140.
Average rating with

Average rating of 4.9 out of 5 stars

(4.91/5.00) calculated out of 2950 reviews

Chromium

Our High Gloss Chrome redefines the standard. Through a precise multi-layer process of polishing, nickel plating, and chrome plating, a flawless "Mirror Finish" is created. The surface impresses with its cool, bluish-silver shine and extreme hardness. Thanks to passing the 24-hour salt spray test (NSS), we guarantee maximum corrosion protection and...

Skip product gallery

Series

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 4.9 out of 5 stars

Coming soon

Average rating of 4.8 out of 5 stars

Skip product gallery

Series

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 5 out of 5 stars

Average rating of 4.9 out of 5 stars

Coming soon

Average rating of 4.8 out of 5 stars

3-Hole Basin / Bath Mixer Tap

  • Made of solid brass
  • High-quality chrome plating
  • Mixing valves with ceramic seals
  • The valves close with a 1/4 turn
  • Spout with ceramic insert and border
  • Installation depth of min. 75mm - max. 100mm
  • High-quality aerator
  • The aerator is adjustable, allowing the water flow to be directed to the basin

Shipping

  • Shipping weight: 3.75 Kg
  • Shipping method: Paket

Product Safety Regulation

Manufacturer information:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 13.05.2026, 20:07:33

[pdf] PGMW14
Components
Nr. Komponente Anzahl 1 Grundkörper 1 2 Auslauf 1 3 Ventil 2 4 Adapterstück (69,5 - 101,5mm) 5 5 Zertifikat unter: 0 www.PaulGurkesShop.deNo. Component Quantity 1 Main body 1 2 Spout 1 3 Valve 2 4 Adapter (69.5 - 101.5mm) 5 5 Certificate under: 0 www.PaulGurkesShop.de
Technical Data
Komponente Beschreibung Mischventil Keramikventil mit 90°-Drehung Strahlregler Neoperl, 7,5-9,0 l/min bei 3 bar Oberfläche Verchromt Material Messing DIN 50930-6Component Description Mixing valve Ceramic valve with 90° rotation Aerator Neoperl, 7.5-9.0 l/min at 3 bar Surface Chrome-plated Material Brass DIN 50930-6
Note
Hinweis • Beachten Sie die Einbautiefe von min. 75mm - max. 100mm • Der Auslauf muss mit einem der beiliegenden Adapterstücke je nach Einbautiefe montiert werden • Verlängerungen sind nicht lieferbarNote • Note the installation depth of min. 75mm - max. 100mm • The spout must be installed with one of the enclosed adapters depending on the installation depth • Extensions are not available
Operation
Bedienung • Regeln Sie die Intensität des Wassers durch Öffnen der Ventile (warm/kalt). • Regeln Sie die Temperatur des Wassers durch Mischen von Warmwasser und Kaltwasser.Operation • Regulate the intensity of the water by opening the valves (hot/cold). • Regulate the temperature of the water by mixing hot and cold water.
Installation step 1 - Mounting basic body
1# Installationsschritt - Montage Grundkörper • Steinwand: Für die Montage benötigen Sie ein Installationsloch von min. 300 x 70 x 75mm (Breite x Höhe x Tiefe). • Ständerwand: Befestigen Sie den Grundkörper auf einer massiven Befestigungsplatte. • Beachten Sie die Einbautiefe von min. 75 - max. 100mm. Berücksichtigen Sie insbesondere die Fliesendicke inklusive Fliesenkleber! • Die pinkfarbenen Putzkappen müssen ca. 1cm aus den Fliesen herausschauen.1# Installation step - Mounting basic body • Stone wall: For the installation you need an installation hole of min. 300 x 70 x 75mm (width x height x depth). • Stud wall: Attach the basic body to a solid mounting plate. • Note the installation depth of min. 75 - max. 100mm. Pay special attention to the tile thickness including tile adhesive! • The pink plaster caps must protrude about 1cm from the tiles.
Installation step 2 - Sealing in combination
2# Installationsschritt - Abdichten im Verbund • Dichten Sie die Putzkappen mit Dichtmanschetten (nicht im Lieferumfang enthalten) im Verbund ab. • Legen Sie die Fliesen. Hierbei ist zu beachten, dass die Fliesenausschnitte so exakt wie möglich gefertigt werden.2# Installation step - Sealing in combination • Seal the plaster caps with sealing sleeves (not included) in the composite system. • Lay the tiles. It should be noted that the tile cutouts are made as accurately as possible.
Installation step 3 - Final assembly
3# Installationsschritt - Endmontage • Schneiden Sie die Putzkappen mit einem geeigneten Werkzeug bündig mit den Fliesen ab. • Dichten Sie die Schnittkante der Putzkappen zu den Fliesen mit Silikon ab. • Montieren Sie die Ventile. • Je nach Einbautiefe wird ein anderes Adapterstück (Pos. 4) für den Auslauf (Pos. 2) benötigt. • Wählen Sie das passende Adapterstück, um den Auslauf bündig mit den Fliesen zu montieren.3# Installation step - Final assembly • Cut the plaster caps flush with the tiles using a suitable tool. • Seal the cut edge of the plaster caps to the tiles with silicone. • Install the valves. • Depending on the installation depth, a different adapter (item 4) is required for the spout (item 2). • Select the appropriate adapter to mount the spout flush with the tiles.
Cleaning & Maintenance
Säuberung & Wartung Um eine gleichbleibende Qualität zu gewährleisten, ist folgendes zu beachten: • Mit sauberem Wasser abspülen & mit Mikrofasertuch trocknen. • Schmutz nur mit milden Reinigungsmitteln entfernen. • Benutzen Sie keine Scheuermilch, Polierpaste, Papiertücher, etc. • Benutzen Sie keine säurehaltigen Reinigungsmittel oder Seife.Cleaning & Maintenance To ensure consistent quality, please note the following: • Rinse with clean water and dry with a microfiber cloth. • Remove dirt only with mild detergents. • Do not use scouring milk, polishing paste, paper towels, etc. • Do not use acidic cleaners or soap.
PaulGurkes Quality
PaulGurkes Qualität • Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt. • Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle. • Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns. Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.PaulGurkes Quality • Congratulations on purchasing your PaulGurkes quality product. Our products are technically sophisticated and manufactured using high-quality materials. • Each product undergoes a hand-picked quality control. • If you are not satisfied with our products, please contact us. We reserve the right to make updates, changes or additions to the information and data provided.
[pdf] Analysebericht-PGMW14
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Report Information
Bericht-Nr.: #2020-1166Report No.: #2020-1166
Herstellernummer: PGMW14Manufacturer Number: PGMW14
Material Composition Analysis
Kupfer Cu 59,525 ± 0,498 58,000 63,000Copper Cu 59.525 ± 0.498 58.000 63.000
Zink Zn 38,555 ± 0,438 33,500 41,500Zinc Zn 38.555 ± 0.438 33.500 41.500
Blei Pb 1,537 ± 0,140 0,200 1,400Lead Pb 1.537 ± 0.140 0.200 1.400
Eisen Fe 0,114 ± 0,038 0,000 0,300Iron Fe 0.114 ± 0.038 0.000 0.300
Zinn Sn 0,096 ± 0,062 0,000 0,500Tin Sn 0.096 ± 0.062 0.000 0.500
Nickel Ni 0,086 ± 0,036 0,000 0,200Nickel Ni 0.086 ± 0.036 0.000 0.200
Mangan Mn 0,000 ± 0,048 0,000 0,050Manganese Mn 0.000 ± 0.048 0.000 0.050
Silizium Si 0,000 0,050Silicon Si 0.000 0.050
Aluminium Al 0,300 0,900Aluminum Al 0.300 0.900
Compliance and Material Information
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The verification of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency regarding the "assessment principles for metallic materials in contact with drinking water" - UBA positive list. According to the German Federal Environment Agency, the material complies with the DIN 50930-6 standard, which specifies statements regarding corrosion resistance.
Werkstoff: CC757S (CuZn39PblAl)Material: CC757S (CuZn39PblAl)
Signatures and Dates
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, Montag, 13. Januar 2020Hildesheim, Monday, January 13, 2020
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Technology & Quality Assurance
Footer Information
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 13.01.2020).German Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on January 13, 2020).

[PDF] Allgemeine Pflegehinweise

Analysis Reports - PGMW14 - Version 1
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided. The tested material complies with the Federal Environment Agency's requirements regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the standard DIN 50930-6, which provides information on corrosion resistance.
Material and Identification
Werkstoff: CC757S (CuZn39Pb1Al) Material: CC757S (CuZn39Pb1Al)
Bericht-Nr.: #2020-1166 Report No.: #2020-1166
Herstellernummer: PGMW14 Manufacturer Number: PGMW14
EAN: 4250914816471 EAN: 4250914816471
Measurement and Test Details
Analysenbericht: XL2-99147 Analysis Report: XL2-99147
Messung Nr.: 1166 Measurement No.: 1166
Modus: Legierungen Mode: Alloys
Messdauer: 11,6s Measurement Duration: 11.6s
Zeit: 13.01.2020 13:29:29 Time: 13.01.2020 13:29:29
Werkstoffvorschlag: CC575S_CuZn39Pb1Al Material Suggestion: CC575S_CuZn39Pb1Al
Element Analysis
Kupfer Cu: 59,525 ± 0,498 % (Min: 58,000, Max: 63,000) Copper Cu: 59.525 ± 0.498 % (Min: 58.000, Max: 63.000)
Zink Zn: 38,555 ± 0,438 % (Min: 33,500, Max: 41,500) Zinc Zn: 38.555 ± 0.438 % (Min: 33.500, Max: 41.500)
Blei Pb: 1,537 ± 0,140 % (Min: 0,200, Max: 1,400) Lead Pb: 1.537 ± 0.140 % (Min: 0.200, Max: 1.400)
Eisen Fe: 0,114 ± 0,038 % (Min: 0,000, Max: 0,300) Iron Fe: 0.114 ± 0.038 % (Min: 0.000, Max: 0.300)
Zinn Sn: 0,096 ± 0,062 % (Min: 0,000, Max: 0,500) Tin Sn: 0.096 ± 0.062 % (Min: 0.000, Max: 0.500)
Nickel Ni: 0,086 ± 0,036 % (Min: 0,000, Max: 0,200) Nickel Ni: 0.086 ± 0.036 % (Min: 0.000, Max: 0.200)
Mangan Mn: 0,000 ± 0,048 % (Min: 0,000, Max: 0,050) Manganese Mn: 0.000 ± 0.048 % (Min: 0.000, Max: 0.050)
Silizium Si: Min: 0,000, Max: 0,050 Silicon Si: Min: 0.000, Max: 0.050
Aluminium Al: Min: 0,300, Max: 0,900 Aluminum Al: Min: 0.300, Max: 0.900
Contact Person and Location
Olaf Manusch, Geschäftsführer Olaf Manusch, Managing Director
Marc Manusch, Leitung Technik & Qualitätswesen Marc Manusch, Head of Engineering & Quality Management
Klingenbergstr. 12, 31139 Hildesheim Klingenbergstr. 12, 31139 Hildesheim
Hildesheim, Montag, 13. Januar 2020 Hildesheim, Monday, January 13, 2020
Ablaufgarnitur: Without waste set
Ausführung: Badarmatur
Material: Messing
Montageart: Unterputz Wandmontage
Variante: Waschtischarmatur Unterputz
Application: Cold and hot water supply
Application area: Washbasin
Article type: Tap
Colour: Chrome
Connection: High pressure – pressure-resistant
Connection type: Concealed installation unit (included in delivery)
Finish: Glossy
Form: Rund
Serie: Neptun

1 of 1 reviews

Average rating of 5 out of 5 stars


100%

0%

0%

0%

0%


Leave a review!

Share your experiences with other customers.


1 review

1 June 2020 - Simone Fischer 🇩🇪 Germany
Verified purchase

Review with rating of 5 out of 5 stars

Top quality
AI-translated (Original language: de-DE) Show original
Loading...

Loading 3D model...

Mouse: Rotate | Scroll: Zoom | Right-click: Pan Finger: Rotate | Pinch: Zoom | Two fingers: Pan