Skip to main content Skip to search Skip to main navigation
Please note our information regarding customs and duties. Delivery available from £140.
Average rating with

Average rating of 4.9 out of 5 stars

(4.91/5.00) calculated out of 2963 reviews

Chromium

Our High Gloss Chrome redefines the standard. Through a precise multi-layer process of polishing, nickel plating, and chrome plating, a flawless "Mirror Finish" is created. The surface impresses with its cool, bluish-silver shine and extreme hardness. Thanks to passing the 24-hour salt spray test (NSS), we guarantee maximum corrosion protection and...

Stand Valve

  • Made of solid brass
  • High-quality chrome-plated
  • Valve with ceramic seals
  • Valve closes with a 1/4 turn
  • For one water connection (cold or hot water)
  • Swiveling spout
  • Without connection hose 
  • Faucet with 1/2" external thread
  • Ø cover plate 5 cm
  • Installation in sinks up to 2.5 cm thickness possible
  • Hole size 2.2 cm to max. 4.5 cm (Optimal: 3.5 cm)

Shipping

  • Shipping weight: 1.1 Kg
  • Shipping method: Paket

Product Safety Regulation

Manufacturer information:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 08.06.2026, 10:36:30

[pdf] PG52T7
Components
Nr. Komponente AnzahlNo. Component Quantity
1 Armatur 11 Faucet 1
2 Dichtung 12 Seal 1
3 Dichtung 13 Seal 1
4 Befestigungsring 14 Mounting ring 1
Mixing element
Mischelement Keramikventil Rotation 90°Mixing element Ceramic valve Rotation 90°
Important information
Wichtig Um die Armatur bei Temperaturen < 0 °C zu schützen, ist diese komplett vom Wasser zu entleeren. Beachten Sie bei der Installation alle erforderlichen gesetzlichen und nationalen Bestimmungen (anerkannte Regeln der Technik) und halten Sie diese ein.Important To protect the fitting at temperatures < 0 °C, it must be completely drained of water. When installing, observe all necessary legal and national regulations (recognized rules of technology) and adhere to them.
Operation
Bedienung • Regeln Sie die Intensität des Wassers wie im Schaubild.Operation • Adjust the intensity of the water as shown.
Installation
Installation • Stecken Sie das Gewinde der Armatur durch die vorgesehene Öffnung des Waschbeckens. • Fixieren Sie die Armatur mit dem vorgesehenen Bauteil. • Schließen Sie einen 1/2" Flexschlauch an das Gewinde des Standventils an. • Entfernen Sie den Luftsprudler und spülen die Leitung mindestens 3 Minuten. • Montieren Sie den Luftsprudler.Installation • Insert the thread of the fitting through the intended opening in the sink. • Secure the fitting with the intended component. • Connect a 1/2" flexible hose to the thread of the angle valve. • Remove the aerator and flush the pipe for at least 3 minutes. • Install the aerator.
Cleaning & Maintenance
Säuberung & Wartung Um eine gleichbleibende Qualität zu gewährleisten, ist folgendes zu beachten: • Mit sauberem Wasser abspülen & mit Mikrofasertuch trocknen. • Schmutz nur mit milden Reinigungsmitteln entfernen. • Benutzen Sie keine Scheuermilch, Polierpaste, Papiertücher, etc. • Benutzen Sie keine säurehaltigen Reinigungsmittel oder Seife.Cleaning & Maintenance To ensure consistent quality, the following should be observed: • Rinse with clean water & dry with a microfiber cloth. • Remove dirt only with mild detergents. • Do not use scouring milk, polishing paste, paper towels, etc. • Do not use acidic cleaning agents or soap.
PaulGurkes Quality
PaulGurkes Qualität • Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt. • Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle. • Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns.PaulGurkes Quality • Congratulations on purchasing your PaulGurkes quality product. Our products are technically sophisticated and made using high-quality materials. • Each product undergoes a hand-picked quality control. • If you are not satisfied with our products, please contact us.
Disclaimer
Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.We reserve the right to make updates, changes or additions to the information and data provided.
[pdf] PG52T7_Anordnungsplan
21 8NM1A20021 8NM1A200 1/2"
20 8SJ1A20020 8SJ1A200 1/2"

[PDF] Allgemeine Pflegehinweise

Analysis Reports - PG52T7 - Version 1
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. The sample was tested using X-ray fluorescence analysis and yielded the following measurement result. Proof of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been established.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. The tested material complies with the requirements of the German Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA Positive List. According to the German Federal Environment Agency, the material complies with the standard DIN 50930-6, which provides information on corrosion resistance.
Material
CW617N (CuZn40Pb2) CW617N (CuZn40Pb2)
Identification
Bericht-Nr.: #2019-1072 Report No.: #2019-1072
Herstellernummer: PG52T7-Ventil Manufacturer Number: PG52T7-Ventil
EAN: 4250914803501 EAN: 4250914803501
Measurement Results
Messung Nr.: 1072 Measurement No.: 1072
Modus: Legierungen Mode: Alloys
Messdauer: 7,5s Measurement Duration: 7.5s
Zeit: 29.07.2019 09:20:42 Time: 29.07.2019 09:20:42
Analysenbericht XL2-99147 Analysis Report XL2-99147
Element Analysis
Element Element
% %
± 2σ ± 2σ
Min Min
Max Max
Kupfer Cu Copper Cu
58,172 58.172
± 0,616 ± 0.616
57,000
Analysis Reports - PG52T7 - Version 1
Analysis Report
Analysis The sample was tested using X-ray fluorescence analysis and provided the following measurement result. Verification of suitability for drinking water installations in accordance with the Drinking Water Regulation (TrinkwV 2001) is hereby established. The tested material complies with the Federal Environment Agency's requirements regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the standard DIN 50930-6, which provides statements regarding corrosion resistance.
Material and Identification
Material CW614N (CuZn39Pb3)
Report Number #2019-921
Manufacturer Number PG52T7-Ventil
EAN 4250914803501
Measurement Data
Measurement Number 921
Mode Alloys
Measurement Duration 6.5s
Time 08.01.2019 12:59:27
Manufacturer Number pg52t7-ventil
Element Analysis
Element % | ±2σ | Min | Max
Copper Cu 58.543 | ±0.671 | 57.000 | 62.000
Zinc Zn 38.772 | ±0.588 | 33.500 | 41.000
Lead Pb 2.510 | ±0.231 | 2.500 | 3.500
Iron Fe 0.087 | ±0.049 | 0.000 | 0.500
Tin Sn 0.000 | ±0.100 | 0.000 | 0.300
Nickel Ni 0.000 | ±0.069 | 0.000 | 0.200
Signatories
Management Olaf Manusch - Managing Director
Management Marc Manusch - Head of Engineering & Quality Management
Manufacturer
Company PaulGurkes GmbH
Address Klingenbergstr. 12
City 31139 Hildesheim
Date and Place
Information Hildesheim, Tuesday, January 8, 2019
Analysis Reports - PG52T7 - Version 1
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. The sample was tested using X-ray fluorescence analysis and yielded the following measurement result. Proof of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus established.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. The tested material complies with the Federal Environment Agency's requirements regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which establishes requirements for corrosion resistance.
Werkstoff: CW617N (CuZn40Pb2) Material: CW617N (CuZn40Pb2)
Bericht-Nr.: #2019-1070 Report Number: #2019-1070
Herstellernummer: PG52T7-Anschlussgewinde Manufacturer Number: PG52T7-Anschlussgewinde
EAN: 4250914803501 EAN: 4250914803501
Place and Date
Hildesheim, Montag, 29. Juli 2019 Hildesheim, Monday, July 29, 2019
Signatories
Olaf Manusch, Geschäftsführer Olaf Manusch, Managing Director
Marc Manusch, Leitung Technik & Qualitätswesen Marc Manusch, Head of Engineering & Quality Assurance
Company
PaulGurkes GmbH PaulGurkes GmbH
Klingenbergstr. 12 Klingenbergstr. 12
31139 Hildesheim 31139 Hildesheim
Analysis Report XL2-99147
Messung Nr.: 1070 Measurement Number: 1070
Modus: Legierungen Mode: Alloys
Messdauer: 7,0s Measurement Duration: 7.0s
Zeit: 29.07.2019 09:17:21 Time: 29.07.2019 09:17:21
Herstellernummer: pg52t7 - gewinde Manufacturer Number: pg52t7 - gewinde
User Login: Marc Manusch User Login: Marc Manusch
Analysis Reports - PG52T7 - Version 1
Analysis Report
Analysis Report The sample was tested using X-ray fluorescence analysis and produced the following measurement results. Proof of suitability for use in drinking water installations in accordance with the Drinking Water Ordinance (TrinkwV 2001) is hereby provided. The tested material complies with the requirements of the Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" – UBA – Positive List. According to the Federal Environment Agency, the material meets the standard DIN 50930-6, which addresses corrosion resistance.
Material and Identification
Material CW617N (CuZn40Pb2)
Report Number #2019-918
Manufacturer Number PG52T7-Anschlussgewinde
EAN 4250914803501
Measurement Results
Analysis Report XL2-99147
Measurement Number 918
Mode Alloys
Measurement Duration 6.8s
Time January 8, 2019 12:50:00
Manufacturer Number pg52t7 - gewinde
User Login Marc Manusch
Material Suggestion CW617N_CuZn40Pb2
Element Analysis
Element % | ± 2σ | Min | Max
Copper Cu 59.472 | ± 0.715 | 57.000 | 60.000
Zinc Zn 38.128 | ± 0.620 | 37.000 | 41.500
Lead Pb 1.947 | ± 0.217 | 1.600 | 2.200
Iron Fe 0.263 | ± 0.070 | 0.000 | 0.300
Tin Sn 0.103 | ± 0.086 | 0.000 | 0.300
Nickel Ni 0.087 | ± 0.052 | 0.000 | 0.100
Aluminum Al 0.000 | | | 0.050
Signatory
Signatories Olaf Manusch, Managing Director
Marc Manusch, Head of Engineering and Quality Management
Manufacturer Information
Manufacturer PaulGurkes GmbH
Klingenbergstr. 12
31139 Hildesheim
Date and Place Hildesheim, Tuesday, January 8, 2019

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Colour: Chrome

2 of 2 reviews

Average rating of 5 out of 5 stars


100%

0%

0%

0%

0%


Leave a review!

Share your experiences with other customers.


2 reviews

29 May 2023 - Ingvall Jan-Erik 🇮🇹 Finland
Verified purchase

Review with rating of 5 out of 5 stars

Simple, beautiful, ergonomic
AI-translated (Original language: de-DE) Show original
8 February 2021 - Annette Freischlad 🇩🇪 Germany
Verified purchase

Review with rating of 5 out of 5 stars

We've had this fixture in the guest toilet for half a year. We are very satisfied. Optically and functionally.
AI-translated (Original language: de-DE) Show original
Loading...

Loading 3D model...

Mouse: Rotate | Scroll: Zoom | Right-click: Pan Finger: Rotate | Pinch: Zoom | Two fingers: Pan