PaulGurkes Concealed Shower Set with Thermostat Scald Protection
Prices excl. VAT plus shipping costs
Dispatch by 10 June 2026 — Delivery time : 4-5 Days
Operation
- The upper switch is used to select the outlets, such as hand shower or rain shower. Additionally, the water intensity can be adjusted between the settings.
- The lower switch regulates the water temperature. Due to the 38°C scald protection, a safety button on the lower control must be pressed to allow further adjustment of the thermostat.
General Data
- 2-way thermostat faucet
- Equipped with a high-quality brand thermostat cartridge
- Backflow prevention compliant with DIN EN 1717
- Hot/cold water supply secured with backflow preventer
- Made entirely of solid brass
- With high-quality chrome plating
- Internal thread 1/2"
- Installation depth 55-90 mm
Note
This item comes with an integrated base body and is ready for installation; no additional components are required.
Head Shower
- Made of stainless steel
- High-gloss polished (like chrome)
- 40 x 40 cm
- Extra thin up to 2 mm
- 196 anti-lime nozzles
- Edges rounded, seamless and screwless
- With ECO flow limiter max. 10 L/min
- Due to the flat design, immediate water stop is achieved
- With chrome-plated brass ball joint
Supply Arm for Head Showers
- Square wall arm
- Made of solid brass
- High-quality chrome plated
- Projection 41 cm
- Pipe 2.5 x 2.5 cm
- Cover plate 5.5 x 5.5 cm
- Thread 1/2"
Wall Connection Bend with Shower Holder
- Square design
- Made of solid brass
- High-quality chrome plating
- Angle of the holder is adjustable
- 1/2" external thread
Hand Shower
- Square stick shower
- Made of solid brass
- High-quality chrome plated
- 1 function
- 44 anti-lime nozzles
- Length 20.1 cm (with thread 21.3 cm)
- 2.5 x 2.5 cm
Shower Hose Length 150 cm
- The double-sided 1/2" swivel cones prevent twisting of the hose
- High-quality plastic hose with smooth surface, reinforced with polyester threads (cross-weave)
- The smooth surface offers excellent cleaning possibilities
- The silver-gloss surface achieves a metallic effect
- Swivel cones made of solid brass, high-quality chrome plated
- Certified: KTW recommendation, EN 1113, NF077
- Made in Germany
Shipping
- Shipping weight: 7.34 Kg
- Shipping method: Paket
Product Safety Regulation
Manufacturer information:
Name des Herstellers: PaulGurkes GmbH
Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland
Elektronische Adresse: anfrage@paulgurkesshop.de
Letztes Update: 08.06.2026, 10:20:38
Documents of the products included in the set
PGJ7-2W
| Analysebericht | Analysis Report |
| Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. | The sample was tested using X-ray fluorescence analysis and has produced the following measurement result. |
| Bericht-Nr.: | Report No.: |
| Herstellernummer: | Manufacturer Number: |
| Kupfer | Copper |
| Zink | Zinc |
| Blei | Lead |
| Eisen | Iron |
| Zinn | Tin |
| Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. | The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided. |
| Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der "Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. | The tested material complies with the requirements of the Federal Environment Agency regarding the "Assessment bases for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which presents statements regarding corrosion resistance. |
| Werkstoff: | Material: |
| Geschäftsführer | Managing Director |
| Leitung Technik & Qualitätswesen | Head of Engineering & Quality Assurance |
| Umweltbundesamt: "Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser", (abgerufen am 03.04.2017). | Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 03.04.2017). |
| Component List |
Analysis Report
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||