Skip to main content Skip to search Skip to main navigation
Please note our information regarding customs and duties. Delivery available from £140.
Average rating with

Average rating of 4.9 out of 5 stars

(4.91/5.00) calculated out of 2920 reviews

Concealed Faucet

  • Featuring a high-quality brand ceramic cartridge
  • Includes a 2-way diverter
  • The faucet is made entirely of solid brass
  • Premium chrome finish
  • 1/2" standard internal thread

Operation

  • The upper diverter allows switching between outlets. After turning off the water with the lower single lever mixer, the diverter returns to its original position. In the rest position, the lower outlet is active.

Note

This item comes with an integrated base body and is ready for installation; no additional components are required.

Rain Shower

  • Made of solid brass
  • Premium chrome finish
  • 30 x 30 x 1 cm
  • 324 anti-limescale nozzles (very fine rain)
  • High quality, easy to clean due to the screw connection on the back
  • 1/2" ball joint

Supply Arm for Head Showers

  • Square ceiling arm
  • Made of solid brass
  • Chrome plated
  • Length 30 cm
  • Pipe 2.5 x 2.5 cm
  • Cover plate 5.8 x 5.8 cm
  • 1/2" thread

Wall Connection Bend with Shower Holder

  • Square design
  • Made of solid brass
  • With premium chrome plating
  • 1/2" external thread

Hand Shower

  • Square stick shower
  • Made of solid brass
  • Premium chrome finish
  • 1 function
  • 44 anti-limescale nozzles
  • Length 20.1 cm (with thread 21.3 cm)
  • 2.5 x 2.5 cm

Shower Hose Length 160 cm

  • The dual 1/2" swivel cones prevent twisting of the hose. <\/strong>
  • Made of stainless steel, high-gloss polished
  • Double winding (overlapping) for high tensile strength
  • Kink-resistant, durable, flexible
  • Swivel cones made of solid brass, premium chrome plated
  • Certified: KTW recommendation, EN 1113, NF077
  • Made in Germany

Shipping

  • Shipping weight: 5.91 Kg
  • Shipping method: Paket

Product Safety Regulation

Manufacturer information:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 08.04.2026, 18:44:10

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Weitere Kundenbilder zu im Set enthaltenen Produkten

PaulGurkes Concealed Shower Mixer Bathtub Faucet Square with Diverter

PGVM34

£119*

PaulGurkes 30cm Square Rain Shower

PGHPMSHE30

£178*

PaulGurkes Ceiling Shower Arm Square 30cm

PGHPEDA

£29*

PaulGurkes Square Hand Shower in Brass

PGHPBHS010

£28*

PaulGurkes Wall Connector with Holder for Square Hand Showers

PGHP007

£37*

PaulGurkes Stainless Steel Shower Hose 160cm with Swivel Connectors

PGdoubleAgraff160

£16*

Documents of the products included in the set

PGVM34

[pdf] Analysebericht-PGVM34
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following result.
Report Information
Bericht-Nr.: #2017-29Report No.: #2017-29
Herstellernummer: PGVM34Manufacturer Number: PGVM34
Material Composition
Kupfer Cu 59,625 ± 0,330 58,000 61,000Copper Cu 59.625 ± 0.330 58.000 61.000
Zink Zn 38,507 ± 0,291 37,000 40,000Zinc Zn 38.507 ± 0.291 37.000 40.000
Blei Pb 1,685 ± 0,098 1,500 2,500Lead Pb 1.685 ± 0.098 1.500 2.500
Eisen Fe 0,049 ± 0,021 0,000 0,310Iron Fe 0.049 ± 0.021 0.000 0.310
Compliance and Material Information
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus proven.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Environment Agency (Umweltbundesamt) regarding the "Assessment basis for metallic materials in contact with drinking water" - UBA positive list. According to the German Environment Agency, the material meets the DIN 50930-6 standard, which specifies statements regarding corrosion resistance.
Werkstoff: CW617N (CuZn39Pb2)Material: CW617N (CuZn39Pb2)
Signatures and Date
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, Montag, 3. April 2017Hildesheim, Monday, April 3, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Technology & Quality Assurance
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).German Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 03.04.2017).
[pdf] PGVM34
Components
Nr. Komponente AnzahlNo. Component Quantity
1 Unterputzelement 11 Concealed element 1
2 Blende 12 Cover plate 1
4 Madenschraube 14 Grub screw 1
5 Griff 15 Handle 1
6 Umstellerknopf 16 Diverter knob 1
Zertifikat unter: 7 1 www.PaulGurkesShop.deCertificate under: 7 1 www.PaulGurkesShop.de
Technical Data Ceramic Cartridge
Technische Daten KeramikkartuscheTechnical Data Ceramic Cartridge
KTW-Zulassung für TrinkwasserKTW approval for drinking water
Empfohlener Druck 1-5 BarRecommended pressure 1-5 Bar
Öffnungswinkel 25°Opening angle 25°
Maximale Temperatur 90°Maximum temperature 90°
Lebensdauer 70.000 Zyklen (EN 817)Lifespan 70,000 cycles (EN 817)
Operation
BedienungOperation
• Standardmäßig ist der untere Ausgang aktiv. Nach Betätigen des Umstellers der obere Ausgang. • Nach Abstellen des Wassers springt der Umsteller in seine Ausgangsposition zurück.• The lower outlet is active by default. After actuating the diverter, the upper outlet. • After turning off the water, the diverter returns to its starting position.
Installation Instructions
MontagehinweisInstallation Instructions
• Um das Unterputzelement weit genug aus der Wand zu holen, sind zwei 90° 1/2" Winkel geeignet. Die in der Wand verlegten Zuleitungen können dadurch tiefer in der Wand liegen. • Achten Sie insbesondere dadrauf, dass die Verjüngung des Umstellers nach der Installation aus der Abdeckblende hervorschaut und der dickere Teil des Umstellers mit der Blende abdichtet. • Die zwei Zentimeter können für den Fliesenspiegel genutzt werden. Achten Sie insbesondere auf die Einbautiefe von 5,5cm. • Sollte die Armatur zu tief in die Wand gebaut sein, dann ist der Umsteller nicht zu Bedienen. • Sanitärinstallateur und Fliesenleger müssen sich gegenseitig koordinieren, damit die Armatur nicht zu tief in die Wand montiert wird.• To get the concealed element far enough out of the wall, two 90° 1/2" angles are suitable. The supply lines laid in the wall can therefore be deeper in the wall. • In particular, make sure that the taper of the diverter protrudes from the cover plate after installation and that the thicker part of the diverter seals with the cover plate. • The two centimeters can be used for the tile mirror. Pay particular attention to the installation depth of 5.5cm. • If the fitting is built too deep into the wall, the diverter cannot be operated. • Plumbers and tilers must coordinate with each other so that the fitting is not mounted too deep in the wall.
Analysis Reports - PGVM34 - Version 1
Analysis Report
3 1 139 Hildesheim 3 1 139 Hildesheim
Analysenbericht XL2-99147 Analysis Report XL2-99147
Messung Nr.: 29 Measurement No.: 29
Modus: Legierungen Mode: Alloys
Messdauer: 25,5s Measurement Duration: 25.5s
Zeit: 07.03.2017 18:41:37 Time: 07.03.2017 18:41:37
Herstellernummer PGVM34 Manufacturer Number PGVM34
User Login Marc Manusch User Login Marc Manusch
Werkstoffvorschlag: C377ForgBs Material Suggestion: C377ForgBs
Element
Kupfer Cu 59,625 ± 0,330 58,000 61,000 Copper Cu 59.625 ± 0.330 58.000 61.000
Zink Zn 38,507 ± 0,291 37,000 40,000 Zinc Zn 38.507 ± 0.291 37.000 40.000
Blei Pb 1,685 ± 0,098 1,500 2,500 Lead Pb 1.685 ± 0.098 1.500 2.500
Eisen Fe 0,049 ± 0,021 0,000 0,310 Iron Fe 0.049 ± 0.021 0.000 0.310
Measurement Result and Evidence
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. The proof of suitability for drinking water installations according to the Drinking Water Regulation (TrinkwV 2001) is hereby provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA-Positivliste. The tested material complies with the requirements of the German Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list.
Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. According to the Federal Environment Agency, the material meets the standard DIN 50930-6, which addresses statements regarding corrosion resistance.
Material and Documentation
Werkstoff: CW617N (CuZn39Pb2) Material: CW617N (CuZn39Pb2)
Bericht-Nr.: #2017-29 Report No.: #2017-29
Herstellernummer: PGVM34 Manufacturer Number: PGVM34
EAN: 4250914802368 EAN: 4250914802368
Signatures and Date
Olaf Manusch Geschäftsführer Olaf Manusch Managing Director
Hildesheim, Montag, 3. April 2017 Hildesheim, Monday, April 3, 2017
Marc Manusch Leitung Technik & Qualitätswesen Marc Manusch Head of Engineering & Quality Management
References
Umweltbundesamt: „ Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser ", (abgerufen am 03.04.2017). German Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (retrieved 03.04.2017).

PGHPEDA

[pdf] Analysebericht-Brausearm
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Report Information
Bericht-Nr.: #2017-261Report No.: #2017-261
Herstellernummer: PGHPEDA 10/20/30Manufacturer Number: PGHPEDA 10/20/30
Element Composition
Kupfer Cu 63,235 ± 0,555 63,000 64,500Copper Cu 63.235 ± 0.555 63.000 64.500
Zink Zn 36,371 ± 0,456 34,500 37,000Zinc Zn 36.371 ± 0.456 34.500 37.000
Eisen Fe 0,185 ± 0,044 0,000 0,300Iron Fe 0.185 ± 0.044 0.000 0.300
Blei Pb 0,131 ± 0,056 0,000 0,200Lead Pb 0.131 ± 0.056 0.000 0.200
Zinn Sn 0,000 ± 0,238 0,000 0,300Tin Sn 0.000 ± 0.238 0.000 0.300
Arsen As 0,000 ± 0,069 0,040 0,140Arsenic As 0.000 ± 0.069 0.040 0.140
Mangan Mn 0,000 ± 0,057 0,000 0,100Manganese Mn 0.000 ± 0.057 0.000 0.100
Aluminium Al 0,200 0,700Aluminum Al 0.200 0.700
Compliance Statements
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency regarding the "assessment principles for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information on corrosion resistance.
Material Designation
Werkstoff: CuZn35Al-CMaterial: CuZn35Al-C
Signatures and Dates
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, Montag, 3. April 2017Hildesheim, Monday, April 3, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Technology & Quality Assurance
Environmental Agency Reference
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on April 3, 2017).

PGHP007

[pdf] Analysebericht-PGHP007
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Bericht-Nr.: #2017-626 Herstellernummer: PGHP007 EAN: 4250914805376Report No.: #2017-626 Manufacturer number: PGHP007 EAN: 4250914805376
Material Composition
Kupfer Cu 59,113 ± 0,788 57,000 60,000 Zink Zn 38,501 ± 0,689 37,000 41,500 Blei Pb 2,114 ± 0,253 1,600 2,200 Eisen Fe 0,269 ± 0,079 0,000 0,300 Zinn Sn 0,000 ± 0,180 0,000 0,300 Nickel Ni 0,000 ± 0,084 0,000 0,100 Aluminium Al 0,000 0,050Copper Cu 59.113 ± 0.788 57.000 60.000 Zinc Zn 38.501 ± 0.689 37.000 41.500 Lead Pb 2.114 ± 0.253 1.600 2.200 Iron Fe 0.269 ± 0.079 0.000 0.300 Tin Sn 0.000 ± 0.180 0.000 0.300 Nickel Ni 0.000 ± 0.084 0.000 0.100 Aluminium Al 0.000 0.050
Compliance Statements
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Environment Agency regarding the "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the German Environment Agency, the material meets the DIN 50930-6 standard, which sets out statements regarding corrosion resistance.
Material Designation
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Signatures
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, Montag, 3. April 2017Hildesheim, Monday, April 3, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Engineering & Quality Management
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).German Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 03.04.2017).
Analysis Reports - PGHP007 - Version 1
General Information
PaulGurkes GmbH Klingenbergstr. 12 31139 Hildesheim PaulGurkes GmbH Klingenbergstr. 12 31139 Hildesheim
Analysis Report XL2-99147 Analysenbericht XL2-99147
Measurement No.: 626 Messung Nr.: 626
Mode: Alloys Modus: Legierungen
Measurement Duration: 5.0s Messdauer: 5,0s
Time: 29.09.2017 17:08:54 Zeit: 29.09.2017 17:08:54
Manufacturer Number pghp007 - body Herstellernummer pghp007 - body
User Login Marc Manusch User Login Marc Manusch
Material Specification: CW617N_CuZn40Pb2 Werkstoffvorschlag: CW617N_CuZn40Pb2
Element Analysis
Copper Cu: 59.1 13 ± 0.788 (Min: 57.000 Max: 60.000) Kupfer Cu: 59,1 13 ± 0,788 (Min: 57,000 Max: 60,000)
Zinc Zn: 38.501 ± 0.689 (Min: 37.000 Max: 41.500) Zink Zn: 38,501 ± 0,689 (Min: 37,000 Max: 41,500)
Lead Pb: 2.1 14 ± 0.253 (Min: 1.600 Max: 2.200) Blei Pb: 2,1 14 ± 0,253 (Min: 1,600 Max: 2,200)
Iron Fe: 0.269 ± 0.079 (Min: 0.000 Max: 0.300) Eisen Fe: 0,269 ± 0,079 (Min: 0,000 Max: 0,300)
Tin Sn: 0.000 ± 0.180 (Min: 0.000 Max: 0.300) Zinn Sn: 0,000 ± 0,180 (Min: 0,000 Max: 0,300)
Nickel Ni: 0.000 ± 0.084 (Min: 0.000 Max: 0.100) Nickel Ni: 0,000 ± 0,084 (Min: 0,000 Max: 0,100)
Aluminum Al: 0.000 0.050 Aluminium Al: 0,000 0,050
Remarks
* Please enter text here. * * Bitte hier T ext angeben. *
Analysis Reports - PGHP007 - Version 1
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. The sample was tested using X-ray fluorescence analysis and produced the following measurement result.
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. Proof of suitability for use in drinking water installations in accordance with the Drinking Water Ordinance (TrinkwV 2001) is hereby provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. The tested material complies with the requirements of the Federal Environmental Agency regarding the "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list.
Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. According to the Federal Environmental Agency, the material meets the DIN 50930-6 standard, which specifies corrosion resistance requirements.
Material
CW617N (CuZn40Pb2) CW617N (CuZn40Pb2)

[PDF] Allgemeine Pflegehinweise
Application: Cold and hot water supply
Application area: Shower enclosure
Colour: Chrome

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Loading...

Loading 3D model...

Mouse: Rotate | Scroll: Zoom | Right-click: Pan Finger: Rotate | Pinch: Zoom | Two fingers: Pan