Skip to main content Skip to search Skip to main navigation
Please note our information regarding customs and duties. Delivery available from £140.
Early Black Friday 30 new deals every day · 30% off · only 48 hours Ends in   Shop the deals →
4.91 / 5 from 3,007 reviews Delivery time to United Kingdom: approx. 5–11 working days Shipping from £18
Dimensions & installation

Will it fit your situation?

  • Shipping weight5,4 kg
All specifications

Technical data

Application
Cold and hot water supply
Application area
Shower enclosure
Colour
Chrome
Product number:
PGSetVM24051c8w8M13289Q1483
EAN:
4250914802559
Shipping weight
5,4 kg
Customer voices

Reviews

4.91/5

2,969 verified shop reviews. This product has no review of its own yet — share your experience and help others plan their bathroom. We verify all reviews for authenticity.

Concealed Faucet 3-Way

  • All components made of solid brass
  • High-quality chrome finish
  • Durable SEDAL ceramic cartridge
  • 1/2" connections
  • Single lever mixer with 3-way switch
  • For connecting 3 water outlets
  • Minimum installation depth 5 cm

Shower Head

  • Material plastic
  • High-quality chrome finish
  • 20 x 20 cm
  • 1.6 cm thick
  • 144 anti-lime nozzles
  • Thanks to the internal screw connection, this shower head is very high-quality and easy to clean
  • Recommended for hard water regions
  • Brass ball joint

Shower Arm for Shower Heads

  • Square wall arm
  • Made of solid brass
  • High-quality chrome finish
  • Pipe 3.5 x 1.5 cm
  • Length 38.5 cm (without thread 34.5 cm)
  • 1/2" thread

Bathtub Inlet

  • Square design
  • Made of solid brass casting
  • High-quality chrome finish
  • Flow regulator
  • Projection 21 cm
  • Spout 2.2 x 4.5 x 20 cm
  • 1/2" external thread

Wall Connection Bend

  • Square design
  • Made of solid brass
  • High-quality chrome finish
  • Backflow prevention according to DIN EN 1717
  • 1/2" internal thread to wall

Hand Shower

  • Square handheld shower
  • 1 function
  • Made of plastic
  • High-quality chrome finish
  • 48 anti-lime nozzles
  • Length 22 cm (with thread 23 cm)
  • 2.8 x 2.8 cm

Shower Holder

  • Square design
  • Made of plastic
  • High-quality chrome finish
  • The angle of the holder is adjustable

Shower Hose Length 160 cm

  • Thanks to the double-sided 1/2" swivel cones, twisting of the hose is impossible. <\/strong>
  • Made of stainless steel, high-gloss polished
  • Double winding (overlapping) for high tensile strength
  • Kink-resistant, durable, flexible
  • Swivel cones made of solid brass, high-quality chrome finish
  • Certified: KTW recommendation, EN 1113, NF077
  • Made in Germany

Shipping

  • Shipping weight: 5.42 Kg
  • Shipping method: Parcel

Product Safety Regulation

Manufacturer information:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: info@paulgurkesshop.de


Last update: 13 Nov 2026, 10:21:15

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Weitere Kundenbilder zu im Set enthaltenen Produkten

PaulGurkes Concealed Shower Valve 3-Way Square Mixer

PGVM24

£144*

PaulGurkes 20cm Rainshower Showerhead

PG1483

£37*

PaulGurkes Square Bathtub Spout

PG8W

£57*

PaulGurkes Shower Holder for Hand Showers in Plastic for Shower Hoses

PGPH

£11*

PaulGurkes Square Handheld Showerhead Chrome

PG1328a

£15*

PaulGurkes Corner Wall Connector

PG8M

£29*

PaulGurkes Stainless Steel Shower Hose 160cm with Swivel Connectors

PGdoubleAgraff160

£15*

PaulGurkes Wall Arm for Rectangular Shower Heads

PG9Q

£49*

Documents of the products included in the set

PGVM24

[pdf] Analysebericht-PGVM24
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Bericht-Nr.: #2017-50Report No.: #2017-50
Herstellernummer: PGVM24Manufacturer number: PGVM24
Elemental Composition Table
Kupfer Cu 59,565 ± 0,440 57,000 60,000Copper Cu 59.565 ± 0.440 57.000 60.000
Zink Zn 38,726 ± 0,386 37,000 41,500Zinc Zn 38.726 ± 0.386 37.000 41.500
Blei Pb 1,588 ± 0,127 1,600 2,200Lead Pb 1.588 ± 0.127 1.600 2.200
Eisen Fe 0,061 ± 0,029 0,000 0,300Iron Fe 0.061 ± 0.029 0.000 0.300
Zinn Sn 0,000 0,300Tin Sn 0.000 0.300
Aluminium Al 0,000 0,050Aluminum Al 0.000 0.050
Nickel Ni 0,000 0,100Nickel Ni 0.000 0.100
Compliance Statements
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Environment Agency (Umweltbundesamt) regarding the "assessment principles for metallic materials in contact with drinking water" - UBA positive list. According to the German Environment Agency, the material complies with the DIN 50930-6 standard, which provides information on corrosion resistance.
Material Identification
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Signatures and Date
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, Montag, 3. April 2017Hildesheim, Monday, April 3, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Engineering & Quality Assurance
Environmental Agency Note
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).German Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 03.04.2017).
[pdf] PGVM24_Anordnungsplan
Parts list
[pdf] PGVM24-v1.0
Components
Nr. Komponente Anzahl 1 Unterputzelement 1 2 Blende 1 3 Pin & Madenschraube 1 4 Umstellerknopf 1 5 Madenschraube 1 6 Pin 1 7 Griff 1 Zertifikat unter: www.paulgurkesshop.deNo. Component Quantity 1 Concealed element 1 2 Cover plate 1 3 Pin & Grub screw 1 4 Diverter knob 1 5 Grub screw 1 6 Pin 1 7 Handle 1 Certificate at: www.paulgurkesshop.de
Technical Data Ceramic Cartridge
Technische Daten Keramikkartusche KTW-Zulassung für Trinkwasser Empfohlener Druck 1-5 Bar Öffnungswinkel 25° Maximale Temperatur 90° Lebensdauer 70.000 Zyklen (EN 817) Rotation 90°Technical data ceramic cartridge KTW approval for drinking water Recommended pressure 1-5 bar Opening angle 25° Maximum temperature 90° Service life 70,000 cycles (EN 817) Rotation 90°
Operation
Bedienung • Durch drehen der Position des oberen Umstellers kann zwischen den Verbrauchern geschaltet werden. • Regeln Sie die Temperatur und die Intensität wie im unteren Schaubild.Operation • By turning the position of the upper diverter, you can switch between the consumers. • Adjust the temperature and intensity as shown in the diagram below.
Installation Steps
Installationsschritte • Legen Sie die Zuleitungen so, dass diese an die jeweiligen warm/-kaltwasser 1/2" Anschlüsse angeschlossen werden können. • Achten Sie auf die Einbautiefe, sodass der Einhandmischer bedienbar ist. • Fixieren Sie den Unterputzkörper in der Wand, sodass dieser einen festen Sitz hat. • Montieren Sie den Griff.Installation steps • Lay the supply lines so that they can be connected to the respective hot/cold water 1/2" connections. • Pay attention to the installation depth so that the single-lever mixer is operable. • Fix the concealed body in the wall so that it has a firm fit. • Mount the handle.
Cleaning & Maintenance
Säuberung & Wartung Um eine gleichbleibende Qualität zu gewährleisten, ist folgendes zu beachten: • Mit sauberem Wasser abspülen & mit Mikrofasertuch trocknen. • Schmutz nur mit milden Reinigungsmitteln entfernen. • Benutzen Sie keine Scheuermilch, Polierpaste, Papiertücher, etc. • Benutzen Sie keine säurehaltigen Reinigungsmittel oder Seife.Cleaning & Maintenance To ensure consistent quality, please note the following: • Rinse with clean water & dry with a microfibre cloth. • Only remove dirt with mild detergents. • Do not use scouring milk, polishing paste, paper towels, etc. • Do not use acidic cleaning agents or soap.
PaulGurkes Quality
PaulGurkes Qualität • Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt. • Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle. • Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns. Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.PaulGurkes Quality • Congratulations on purchasing your PaulGurkes quality product. Our products are technically sophisticated and manufactured using high-quality materials. • Each product undergoes a hand-picked quality control. • If you are not satisfied with our products, please contact us. We reserve the right to make updates, changes or additions to the information and data provided.

PG8W

[pdf] Analysebericht-PG8W
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Report Details
Bericht-Nr.: #2017-477Report No.: #2017-477
Herstellernummer: PG8WManufacturer Number: PG8W
Element Analysis Table
Kupfer Cu 61,284 ± 2,563 58,000 63,000Copper Cu 61.284 ± 2.563 58.000 63.000
Zink Zn 37,436 ± 2,099 33,500 41,500Zinc Zn 37.436 ± 2.099 33.500 41.500
Blei Pb 1,278 ± 0,598 0,200 1,400Lead Pb 1.278 ± 0.598 0.200 1.400
Zinn Sn 0,000 ± 0,897 0,000 0,500Tin Sn 0.000 ± 0.897 0.000 0.500
Nickel Ni 0,000 ± 0,323 0,000 0,200Nickel Ni 0.000 ± 0.323 0.000 0.200
Eisen Fe 0,000 ± 0,218 0,000 0,300Iron Fe 0.000 ± 0.218 0.000 0.300
Mangan Mn 0,000 ± 0,177 0,000 0,050Manganese Mn 0.000 ± 0.177 0.000 0.050
Silizium Si 0,000 0,050Silicon Si 0.000 0.050
Aluminium Al 0,300 0,900Aluminum Al 0.300 0.900
Compliance Statement
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The evidence of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Environment Agency regarding the "Assessment bases for metallic materials in contact with drinking water" - UBA positive list. According to the German Environment Agency, the material meets the DIN 50930-6 standard, which provides statements regarding corrosion resistance.
Material Designation
Werkstoff: CC757S (CuZn39Pb1Al-C)Material: CC757S (CuZn39Pb1Al-C)
Footer and Signatures
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, 31. August 2017Hildesheim, August 31, 2017
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Engineering & Quality Assurance
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).German Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 03.04.2017).

PG8M

[pdf] PG8M-v1.1
Installation Note
Installationshinweis • Für die Montage benötigen Sie ein 1/2″ Gewindeadapter!Installation Note • For assembly, you need a 1/2″ thread adapter!
Installation
Installation • Stecken Sie die Blende über das 1/2" Gewinde in der Wand. • Drehen Sie den Grundkörper auf das Gewinde. Achten Sie dadrauf, dass Sie die Blende nicht zerkratzen. • Drehen Sie den Duschschlauch auf das vorgesehene Gewinde.Installation • Place the cover over the 1/2" thread in the wall. • Turn the main body onto the thread. Make sure you do not scratch the cover. • Turn the shower hose onto the provided thread.
Cleaning & Maintenance
Säuberung & Wartung Um eine gleichbleibende Qualität zu gewährleisten, ist folgendes zu beachten: • Mit sauberem Wasser abspülen & mit Mikrofasertuch trocknen. • Schmutz nur mit milden Reinigungsmitteln entfernen. • Benutzen Sie keine Scheuermilch, Polierpaste, Papiertücher, etc. • Benutzen Sie keine säurehaltigen Reinigungsmittel oder Seife.Cleaning & Maintenance To ensure consistent quality, observe the following: • Rinse with clean water & dry with a microfiber cloth. • Remove dirt only with mild detergents. • Do not use scouring milk, polishing paste, paper towels, etc. • Do not use acidic detergents or soap.
PaulGurkes Quality
PaulGurkes Qualität • Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt. • Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle. • Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns.PaulGurkes Quality • Congratulations on purchasing your PaulGurkes quality product. Our products are technically sophisticated and manufactured using high-quality materials. • Each product undergoes a hand-picked quality control. • If you are not satisfied with our products, please contact us.

PG9Q

[pdf] Analysebericht-PG9Q
Report header
AnalyseberichtAnalysis report
Bericht-Nr.: #2017-383Report No.: #2017-383
Herstellernummer: PG9QManufacturer number: PG9Q
Test method
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested by X-ray fluorescence analysis and produced the following measurement result.
Measurement details
AnalysenberichtAnalysis report
Messung Nr.: 383 Modus: LegierungenMeasurement No.: 383 Mode: Alloys
Messdauer: 3,7s Zeit: 08.04.2017 11:08:56Measurement duration: 3.7s Time: 08.04.2017 11:08:56
Herstellernummer pg9qManufacturer number pg9q
User Login Marc ManuschUser login Marc Manusch
Werkstoffvorschlag: CC575S_CuZn39Pb1AlMaterial suggestion: CC575S_CuZn39Pb1Al
Composition
Kupfer Cu 61,041 ± 0,989 58,000 63,000Copper Cu 61,041 ± 0,989 58,000 63,000
Zink Zn 37,556 ± 0,854 33,500 41,500Zinc Zn 37,556 ± 0,854 33,500 41,500
Blei Pb 0,990 ± 0,230 0,200 1,400Lead Pb 0,990 ± 0,230 0,200 1,400
Eisen Fe 0,274 ± 0,100 0,000 0,300Iron Fe 0,274 ± 0,100 0,000 0,300
Zinn Sn 0,000 ± 0,213 0,000 0,500Tin Sn 0,000 ± 0,213 0,000 0,500
Mangan Mn 0,000 ± 0,078 0,000 0,050Manganese Mn 0,000 ± 0,078 0,000 0,050
Silizium Si 0,000 0,050Silicon Si 0,000 0,050
Compliance statement
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability for drinking water installations under the Drinking Water Ordinance (TrinkwV 2001) is therefore provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the Federal Environment Agency regarding the „Assessment basis for metallic materials in contact with drinking water“ – UBA positive list. According to the Federal Environment Agency, the material meets the standard DIN 50930-6, which sets out statements on corrosion resistance.
Material
Werkstoff: CC757S (CuZn39Pb1Al-C)Material: CC757S (CuZn39Pb1Al-C)
Signatures
Hildesheim, Samstag, 8. April 2017Hildesheim, Saturday, 8 April 2017
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Engineering & Quality Assurance
* Bitte hier Text angeben. ** Please enter text here. *
References
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).Federal Environment Agency: „Assessment basis for metallic materials in contact with drinking water“, (accessed on 03.04.2017).

[PDF] Allgemeine Pflegehinweise
Application: Cold and hot water supply
Application area: Shower enclosure
Colour: Chrome

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Loading...

Loading 3D model...

Mouse: Rotate | Scroll: Zoom | Right-click: Pan Finger: Rotate | Pinch: Zoom | Two fingers: Pan