Skip to main content Skip to search Skip to main navigation
Please note our information regarding customs and duties. Delivery available from £140.
11.11. Retro-Schwarz-Tage Only 9–12 Nov: up to 35% off black nostalgic taps Ends in   Discover now →
4.91 / 5 from 2,994 reviews Delivery time to United Kingdom: approx. 5–11 working days Shipping from £18
Dimensions & installation

Will it fit your situation?

  • Shipping weight5,5 kg
⤓ Manual & installation plan (PDF)
All specifications

Technical data

Application
Cold and hot water supply
Application area
Shower enclosure
Colour
Chrome
Product number:
PGSET28086T7ME30WDA
EAN:
4250914804522
Shipping weight
5,5 kg
Customer voices

Reviews

4.91/5

2,969 verified shop reviews. This product has no review of its own yet — share your experience and help others plan their bathroom. We verify all reviews for authenticity.

Concealed Mixer Valve

  • All components made of solid brass
  • High-quality chrome finish
  • 1/2" thread
  • Durable ceramic valves from SEDAL
  • Valves close with a 1/4 turn
  • Includes 2-way diverter for two outlets

Rain Shower

  • Made of stainless steel 
  • High-gloss polished (similar to chrome)
  • 30 x 30 cm
  • Extra thin at 2 mm
  • 144 anti-lime nozzles
  • Edges rounded, seamless design
  • Includes ECO flow restrictor max. 10 L/min
  • Flat design allows for immediate water stop
  • With brass ball joint, chrome-plated

Supply Arm for Head Showers

  • Square wall arm
  • Made of solid brass
  • High-quality chrome finish
  • Projection 41 cm
  • Pipe dimensions 2.5 x 2.5 cm
  • Cover plate 5.5 x 5.5 cm
  • 1/2" thread

Wall Connection with Shower Holder

  • Square design
  • Made of solid brass
  • High-quality chrome plating
  • Angle of the holder is adjustable
  • 1/2" external thread

Hand Shower

  • Square handheld shower
  • Made of solid brass
  • High-quality chrome finish
  • 1 function
  • 44 anti-lime nozzles
  • Length 20.1 cm (with thread 21.3 cm)
  • 2.5 x 2.5 cm

Shower Hose Length 160 cm

  • The double-sided 1/2" swivel cones prevent twisting of the hose. 
  • Made of stainless steel, high-gloss polished
  • Double winding (overlapping) for high tensile strength
  • Kink-resistant, durable, flexible
  • Swivel cones made of solid brass, high-quality chrome-plated
  • Certified: KTW recommendation, EN 1113, NF077
  • Made in Germany

Shipping

  • Shipping weight: 5.54 Kg
  • Shipping method: Parcel

Product Safety Regulation

Manufacturer information:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: info@paulgurkesshop.de


Last update: 9 Nov 2026, 21:36:21

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Weitere Kundenbilder zu im Set enthaltenen Produkten

PaulGurkes 3-Hole Concealed Mixer with Cross Handles for Shower and Bathtub

PG28T7

£110*

PaulGurkes 30cm Square Stainless Steel Rain Shower Head

PGHPSSSHE30

£80*

PaulGurkes Wall Arm for Square Shower Head

PG9P

£60*

PaulGurkes Square Hand Shower in Brass

PGHPBHS010

£28*

PaulGurkes Wall Connector with Shower Holder and Hose Connection

PGHPBE006

£39*

PaulGurkes Stainless Steel Shower Hose 160cm with Swivel Connectors

PGdoubleAgraff160

£15*

Documents of the products included in the set

PG28T7

[pdf] PG28T7
Product overview
Unterputz Duscharmatur 2-WegeConcealed shower mixer 2-way
Artikelnummer: PG28T7 / PG28W4Article number: PG28T7 / PG28W4
v1.0 1 von 2v1.0 1 of 2
Components
Unterputzkörper 1Concealed body 1
Keramikventile 2Ceramic valves 2
Dichtung 3Seal 3
Tülle 3Spout 3
Dichtung 3Seal 3
Blende 3Escutcheon 3
Kunststoffeinsatz 2Plastic insert 2
Madenschraube 2Grub screw 2
Griff (je nach Ausführung) 2Handle (depending on version) 2
Umstellergriff 1Diverter handle 1
Zertifikat unter: www.PaulGurkesShop.de 1Certificate at: www.PaulGurkesShop.de 1
Technical data – ceramic valves
KTW-Zulassung für TrinkwasserKTW approval for drinking water
Empfohlener Druck 1-5 BarRecommended pressure 1-5 bar
Maximale Temperatur 90°Maximum temperature 90°
Lebensdauer 200.000 Zyklen (EN 200)Service life 200,000 cycles (EN 200)
Operation
Regeln Sie die Intensität des Wassers wie im linken Schaubild.Adjust the water flow rate as shown in the left-hand diagram.
Regeln Sie die Temperatur des Wassers durch mischen von Warm/-Kaltwasser.Adjust the water temperature by mixing hot/cold water.
AufOpen
ZuClosed
WarmHot
KaltCold
WarmwasserHot water
KaltwasserCold water
Installation steps
Legen Sie die Zuleitungen so, dass diese an die jeweiligen warm/-kaltwasser 1/2“ Anschlüsse angeschlossen werden können.Lay the supply pipes so that they can be connected to the respective hot/cold water 1/2" connections.
Achten Sie auf die Einbautiefe.Pay attention to the installation depth.
Fixieren Sie den Unterputzkörper in der Wand, sodass dieser einen festen Sitz hat.Fix the concealed body in the wall so that it sits firmly.
Schieben Sie den Auslauf vorsichtig auf den Unterputzkörper, achten Sie dabei auf den Blende.Carefully slide the outlet onto the concealed body, paying attention to the escutcheon.
Montieren Sie die Griffe.Fit the handles.
Cleaning and maintenance
Um eine gleichbleibende Qualität zu gewährleisten, ist folgendes zu beachten:To ensure consistent quality, please note the following:
Mit sauberem Wasser abspülen & mit Mikrofasertuch trocknen.Rinse with clean water and dry with a microfibre cloth.
Schmutz nur mit milden Reinigungsmitteln entfernen.Remove dirt only with mild cleaning agents.
Benutzen Sie keine Scheuermilch, Polierpaste, Papiertücher, etc.Do not use abrasive cleaners, polishing paste, paper towels, etc.
Benutzen Sie keine säurehaltigen Reinigungsmittel oder Seife.Do not use acidic cleaning agents or soap.
PaulGurkes quality
Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt.Congratulations on purchasing your PaulGurkes quality product. Our products are technically mature and manufactured using high-quality materials.
Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle.Every product undergoes a hand-selected quality inspection.
Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns.If you are not satisfied with our products, please contact us.
Legal notice
Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.We reserve the right to make updates, changes or additions to the information and data provided.
[pdf] Analysebericht-PG28T7
Analysis Report Introduction
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Report Information
Bericht-Nr.: #2017-63 Herstellernummer: PG28T7 EAN: 4250914801613Report No.: #2017-63 Manufacturer Number: PG28T7 EAN: 4250914801613
Element Composition Table
Kupfer Cu 60,623 ± 0,433 58,000 63,000 Zink Zn 37,793 ± 0,375 33,500 41,500 Blei Pb 1,501 ± 0,122 0,200 1,400 Eisen Fe 0,081 ± 0,030 0,000 0,300 Zinn Sn 0,000 0,500 Aluminium Al 0,300 0,900 Nickel Ni 0,000 0,200 Mangan Mn 0,000 0,050 Silizium Si 0,000 0,050Copper Cu 60.623 ± 0.433 58.000 63.000 Zinc Zn 37.793 ± 0.375 33.500 41.500 Lead Pb 1.501 ± 0.122 0.200 1.400 Iron Fe 0.081 ± 0.030 0.000 0.300 Tin Sn 0.000 0.500 Aluminum Al 0.300 0.900 Nickel Ni 0.000 0.200 Manganese Mn 0.000 0.050 Silicon Si 0.000 0.050
Compliance Statement
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency regarding the "assessment principles for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which sets out statements regarding corrosion resistance.
Material Identification
Werkstoff: CC575S (CuZn39Pb1Al)Material: CC575S (CuZn39Pb1Al)
Signatures and Date
Olaf Manusch Geschäftsführer Hildesheim, Montag, 3. April 2017 Marc Manusch Leitung Technik & QualitätswesenOlaf Manusch Managing Director Hildesheim, Monday, April 3, 2017 Marc Manusch Head of Technology & Quality Assurance
Reference to assessment basis
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 03.04.2017).
[pdf] PG28T7_Anordnungsplan
Components List
Product Manuals - PG28T7 - Version 1
Product Information
PaulGurkes 3-Loch Armatur ohne Griffe PaulGurkes 3-hole mixer tap without handles
Unterputz Duscharmatur 2-Wege Built-in shower mixer, 2-way
Artikelnummer: PG28T7 / PG28W4 Article number: PG28T7 / PG28W4
Components
1 Unterputzkörper 1 1 Built-in mixer body 1
2 Keramikventile 2 2 Ceramic valves 2
3 Dichtung 3 3 Seal 3
4 Tülle 3 4 Spout 3
5 Dichtung 3 5 Seal 3
6 Blende 3 6 Trim ring 3
7 Kunststoffeinsatz 2 7 Plastic insert 2
8 Madenschraube 2 8 Set screw 2
9 Griff (je nach Ausführung) 2 9 Handle (depending on version) 2
10 Umstellergriff 1 10 Diverter handle 1
11 Zertifikat unter: www.PaulGurkesShop.de 1 11 Certificate at: www.PaulGurkesShop.de 1
Technical Data Ceramic Valves
KTW-Zulassung für Trinkwasser KTW approval for drinking water
Empfohlener Druck 1-5 Bar Recommended pressure 1-5 bar
Maximale Temperatur 90° Maximum temperature 90°
Lebensdauer 200.000 Zyklen (EN 200) Lifespan 200,000 cycles (EN 200)
Rotation 90° Rotation 90°
Operation
Regeln Sie die Intensität des Wassers wie im linken Schaubild. Adjust the water intensity as shown in the diagram on the left.
Regeln Sie die Temperatur des Wassers durch mischen von Warm/-Kaltwasser. Adjust the water temperature by mixing hot and cold water.
Installation Steps
Legen Sie die Zuleitungen so, dass diese an die jeweiligen warm/-kaltwasser 1/2" Anschlüsse angeschlossen werden können. Lay the supply lines so they can be connected to the respective hot/cold water 1/2" connections.
Achten Sie auf die Einbautiefe. Pay attention to the installation depth.
Fixieren Sie den Unterputzkörper in der Wand, sodass dieser einen festen Sitz hat. Secure the built-in mixer body in the wall so it has a firm fit.
Schieben Sie den Auslauf vorsichtig auf den Unterputzkörper, achten Sie dabei auf den Blende. Carefully slide the spout onto the built-in body, paying attention to the trim ring.
Montieren Sie die Griffe. Install the handles.
PaulGurkes Quality
Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt. Congratulations on your purchase of a PaulGurkes quality product. Our products are technically refined and manufactured using high-quality materials.
Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle. Each product undergoes careful quality control.
Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns. If you are not satisfied with our products, please contact us.
Cleaning & Maintenance
Um eine gleichbleibende Qualität zu gewährleisten, ist folgendes zu beachten: To ensure consistent quality, the following should be observed:
Mit sauberem Wasser abspülen & mit Mikrofasertuch trocknen. Rinse with clean water and dry with microfiber cloth.
Schmutz nur mit milden Reinigungsmitteln entfernen. Remove dirt only with mild cleaning agents.
Benutzen Sie keine Scheuermilch, Polierpaste, Papiertücher, etc. Do not use abrasive cream, polishing paste, paper towels, etc.
Benutzen Sie keine säurehaltigen Reinigungsmittel oder Seife. Do not use acid-based cleaning agents or soap.
Legal Notice
Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen. We reserve the right to make updates, changes, or additions to the information and data provided.
Layout Plans - PG28T7 - Version 1
Components
No. 1 80T24104
No. 2 K20B17482
No. 3 8JT28086
No. 4 K20A24480
No. 5 8J235x95x5
No. 6 81T34014
No. 7 8J32X215
No. 8 8ZB34014
No. 9 81P24T73
No. 10 8EM4X3
No. 11 80P24T72
No. 12 80P20S92
No. 13 8FM4X10
No. 14 81N82M60
No. 15 80N82M60
No. 16 8HT00002
Layout Plans - PG28T7 - Version 1
Components
1 80T24104
2 K20B17482
3 8JT28086
4 K20A24480
5 8J235x95x5
6 81T34014
7 8J32X215
8 8ZB34014
9 81P24T73
10 8EM4X3
11 80P24T72
12 80P20S92
13 8FM4X10
14 81N82M60
15 80N82M60
16 8HT00002
Manufacturer
Manufacturer PaulGurkes GmbH

PGHPSSSHE30

[pdf] Wartungsplan_Kopfbrause
Wartungsplan
WartungsplanMaintenance Schedule
DatumDate
1. Wartung:1st Maintenance:
2. Wartung:2nd Maintenance:
3. Wartung:3rd Maintenance:
4. Wartung:4th Maintenance:
5. Wartung:5th Maintenance:
6. Wartung:6th Maintenance:
7. Wartung:7th Maintenance:
8. Wartung:8th Maintenance:
Dies gilt nicht als Nachweis der Wartungen!This does not serve as proof of maintenance!
Kontaktdaten
Ihr PaulGurkes TeamYour PaulGurkes Team
Einleitung
Um eine gleichbleibende Qualität und Funktionalität Ihrer Kopfbrause sicherzustellen, ist eine regelmäßige Wartung notwendig. Der je nach Region unterschiedliche Kalkgehalt des Wassers ist dafür verantwortlich, in welchen Intervallen Sie Ihre Kopfbrause entkalken müssen.To ensure consistent quality and functionality of your shower head, regular maintenance is necessary. The varying lime content of the water, depending on the region, is responsible for the intervals at which you need to descale your shower head.
Anleitung
AnleitungInstructions
1. Prüfen Sie ob die Kopfbrause ein gerades Strahlbild hat.1. Check if the shower head has a straight spray pattern.
2. Wenn das Strahlbild unruhig fällt ist die Kopfbrause verkalkt. Löser Sie leichte Verkalkungen, indem Sie mit den Fingern während des Duschvorgangs über die Düsen rubbeln.2. If the spray pattern is uneven, the shower head is calcified. Loosen slight calcifications by rubbing your fingers over the nozzles during showering.
3. Prüfen Sie erneut das Strahlbild.3. Check the spray pattern again.
4. Bei starken Verkalkungen oder hartem Wasser ist die Kopfbrause regelmäßig mit geeignetem Kalklöser komplett zu behandeln.4. For heavy calcification or hard water, the shower head should be completely treated regularly with a suitable descaler.
Wird keine regelmäßige Wartung vorgenommen, kann die Kopfbrause aufgrund der Verkalkung platzen!If regular maintenance is not performed, the shower head may burst due to calcification!

PGHPBE006

[pdf] Analysebericht-pghpbe006
Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested by X-ray fluorescence analysis and yielded the following measurement result.
Report Information
Bericht-Nr.: #2017-575Report No.: #2017-575
Herstellernummer: PGHPBE006Manufacturer Number: PGHPBE006
Element Composition
Kupfer Cu 58,663 ± 0,885 57,000 60,000Copper Cu 58.663 ± 0.885 57.000 60.000
Zink Zn 38,885 ± 0,760 37,000 41,500Zinc Zn 38.885 ± 0.760 37.000 41.500
Blei Pb 2,216 ± 0,268 1,600 2,200Lead Pb 2.216 ± 0.268 1.600 2.200
Eisen Fe 0,234 ± 0,079 0,000 0,300Iron Fe 0.234 ± 0.079 0.000 0.300
Zinn Sn 0,000 ± 0,258 0,000 0,300Tin Sn 0.000 ± 0.258 0.000 0.300
Nickel Ni 0,000 ± 0,080 0,000 0,100Nickel Ni 0.000 ± 0.080 0.000 0.100
Aluminium Al 0,000 0,050Aluminium Al 0.000 0.050
Compliance Statements
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The verification of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency regarding the "Assessment principles for metallic materials in contact with drinking water"- UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information regarding corrosion resistance.
Material Information
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Signatures and Dates
Hildesheim, Montag, 3. April 2017Hildesheim, Monday, April 3, 2017
Olaf Marusch GeschäftsführerOlaf Marusch Managing Director
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Engineering & Quality Management
Footer
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 03.04.2017).

[PDF] Allgemeine Pflegehinweise
Application: Cold and hot water supply
Application area: Shower enclosure
Colour: Chrome

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Loading...

Loading 3D model...

Mouse: Rotate | Scroll: Zoom | Right-click: Pan Finger: Rotate | Pinch: Zoom | Two fingers: Pan