PaulGurkes Copper Wall-Mounted Shower System Retro Set
Prices excl. VAT plus shipping costs
No longer available
Shower System
- Made entirely of solid brass
- High-quality finish
- Designed for connecting a shower fixture
- 2-way diverter for rain shower & hand shower
- Installation with two wall plates
- Each wall plate can be secured with 4 screws
- The wall arm is adjustable in angle and height
Shower Head
- Constructed from solid brass
- High-quality finish - Copper/Red Bronze
- Diameter 20 cm
- Anti-lime nozzles
- ECO flow restrictor max 10 L/min
- 1/2" ball joint
Shower Fixture
- High-quality mixer valve with ceramic cartridge (EN 817)
- Made of solid brass
- High-quality finish
- High-pressure fixture suitable for gas heaters, instant water heaters, and all pressure systems
- Backflow protection according to DIN EN 1717
- 1/2" connections
Retro/Nostalgic Hand Shower
- Made of solid brass
- High-quality finish
- Ceramic handle
- 1 function
- Anti-lime nozzles
- Length 21.5 cm
- Diameter head 7.5 cm
- 1/2" connection
- Compatible with all standard shower hoses
Shipping
- Shipping weight: 8.46 Kg
- Shipping method: Paket
Product Safety Regulation
Manufacturer information:
Name des Herstellers: PaulGurkes GmbH
Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland
Elektronische Adresse: anfrage@paulgurkesshop.de
Letztes Update: 09.06.2026, 07:19:42
Documents of the products included in the set
PGCLASSIC33-RB
Retro Shower Mixer
|
|||||||||||||||
Components
|
|||||||||||||||
Technical Specifications
|
|||||||||||||||
Operation
|
|||||||||||||||
Installation Steps
|
|||||||||||||||
PaulGurkes Quality
|
|||||||||||||||
Care Instructions
|
|||||||||||||||
Legal Notice
|
|||||||||||||||
Analysis Report
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
Material and Documentation
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
Measurement Results
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
Element Analysis
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
Signatories and Address
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
| Analysis Report | |
| The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The evidence of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided. | The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The evidence of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided. |
| The tested material complies with the requirements of the Federal Environment Agency regarding the "Evaluation criteria for metallic materials in contact with drinking water" - UBA positive list. | The tested material complies with the requirements of the Federal Environment Agency regarding the "Evaluation criteria for metallic materials in contact with drinking water" - UBA positive list. |
| The material meets, according to the Federal Environment Agency, the standard DIN 50930-6, which presents statements regarding corrosion resistance. | The material meets, according to the Federal Environment Agency, the standard DIN 50930-6, which presents statements regarding corrosion resistance. |
| Material and Identification | |
| Material: CC757S (CuZn39Pb1Al) | Material: CC757S (CuZn39Pb1Al) |
| Report Number: #2022-1396 | Report Number: #2022-1396 |
| Manufacturer Number: PGKY33 | Manufacturer Number: PGKY33 |
| EAN: 4250914821543 | EAN: 4250914821543 |
| Measurement Results | |
| Analysis Report XL2-99147 | Analysis Report XL2-99147 |
| Measurement Number: 1396 | Measurement Number: 1396 |
| Mode: Alloys | Mode: Alloys |
| Measurement Duration: 4.0s | Measurement Duration: 4.0s |
| Time: 01.06.2007 00:26:07 | Time: 01.06.2007 00:26:07 |
| Manufacturer Number: pgky33 | Manufacturer Number: pgky33 |
| Material Suggestion: CC575S_CuZn39Pb1Al | Material Suggestion: CC575S_CuZn39Pb1Al |
| Element Analysis | |
| Element | Element |
| % | % |
| ±2σ | ±2σ |
| Min | Min |
| Max | Max |
| Copper Cu: 58.798 / ±1.084 / 58.000 / 63.000 | Copper Cu: 58.798 / ±1.084 / 58.000 / 63.000 |
| Zinc Zn: 39.362 / ±0.955 / 33.500 / 41.500 | Zinc Zn: 39.362 / ±0.955 / 33.500 / 41.500 |
| Lead Pb: 1.389 / ±0.281 / 0.200 / 1.400 | Lead Pb: 1.389 / ±0.281 / 0.200 / 1.400 |
| Iron Fe: 0.233 / ±0.102 / 0.000 / 0.300 | Iron Fe: 0.233 / ±0.102 / 0.000 / 0.300 |
| Nickel Ni: 0.179 / ±0.089 / 0.000 / 0.200 | Nickel Ni: 0.179 / ±0.089 / 0.000 / 0.200 |
| Tin Sn: 0.000 / ±0.258 / 0.000 / 0.500 | Tin Sn: 0.000 / ±0.258 / 0.000 / 0.500 |
| Manganese Mn: 0.000 / ±0.144 / 0.000 / 0.050 | Manganese Mn: 0.000 / ±0.144 / 0.000 / 0.050 |
| Silicon Si: 0.000 / Max: 0.050 | Silicon Si: 0.000 / Max: 0.050 |
| Aluminum Al: 0.300 / Max: 0.900 | Aluminum Al: 0.300 / Max: 0.900 |
| Responsible Persons | |
| Managing Director: Olaf Manusch | Managing Director: Olaf Manusch |
| Head of Engineering and Quality Management: Marc Manusch | Head of Engineering and Quality Management: Marc Manusch |
| Place and Date: Hildesheim, October 27, 2022 | Place and Date: Hildesheim, October 27, 2022 |
| Address: Klingenbergstr. 12, 31139 Hildesheim | Address: Klingenbergstr. 12, 31139 Hildesheim |
| User Login: Marc Manusch | User Login: Marc Manusch |
PGCLASSIC-RB
Analysis Report Header
| |||||||||||||||||||
Introduction
| |||||||||||||||||||
Report Information
| |||||||||||||||||||
Material Composition Table
| |||||||||||||||||||
Compliance Statement
| |||||||||||||||||||
Material Designation
| |||||||||||||||||||
Signatures
| |||||||||||||||||||
Footer
| |||||||||||||||||||
Surface-Mounted Shower System
|
|||||||||||||||||||||||||
Components
|
|||||||||||||||||||||||||
Operation
|
|||||||||||||||||||||||||
PaulGurkes Quality
|
|||||||||||||||||||||||||
Installation Steps
|
|||||||||||||||||||||||||
Care Instructions
|
|||||||||||||||||||||||||
| Analysis Report | |
| Analysebericht | The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is hereby proven. The tested material complies with the requirements of the Federal Environment Agency regarding "evaluation criteria for metallic materials in contact with drinking water" - UBA positive list. The material meets the DIN 50930-6 standard according to the Federal Environment Agency, which sets forth statements regarding corrosion resistance. |
| Material | |
| Werkstoff | CuZn35Al-C |
| Report Number | |
| Bericht-Nr. | #2020-1224 |
| Manufacturer Number | |
| Herstellernummer | PGCLASSIC / PGCLASSIC-B / PGCLASSIC-ZR / PGCLASSIC-RB |
| EAN | |
| EAN | 4250914817454 / 4250914817133 / 4250914817140 / 4250914817126 |
| Elements | |
| Kupfer (Cu) | Copper (Cu) |
| Zink (Zn) | Zinc (Zn) |
| Eisen (Fe) | Iron (Fe) |
| Nickel (Ni) | Nickel (Ni) |
| Blei (Pb) | Lead (Pb) |
| Zinn (Sn) | Tin (Sn) |
| Arsen (As) | Arsenic (As) |
| Mangan (Mn) | Manganese (Mn) |
| Aluminium (Al) | Aluminum (Al) |
| Signatories | |
| Unterzeichner | Olaf Manusch, Chief Executive Officer |
| ppa. Marc Manusch, Head of Engineering & Quality Management | |
| Date and Location | |
| Datum und Ort | Hildesheim, Friday, December 11, 2020 |
[PDF] Allgemeine Pflegehinweise
| Colour: | Copper |
|---|
Login
1 review
.jpg?ts=1770210784)
.jpg?ts=1770210784)
.jpg?ts=1770210784)