PaulGurkes Concealed Bidet Set with WC Shower Hygienic Spray
Prices excl. VAT plus shipping costs
Dispatch by 22 May 2026 — Delivery time : 4-5 Days
Note
- Ensure the supply lines are protected against backflow using a suitable backflow prevention device.
Mixing Valve
- Body made of solid brass
- High-quality chrome finish
- Durable Sedal ceramic cartridge
- 1/2" thread
- For a single user
- Convenient single lever mixer
- Cover plate Ø110mm
Wall Connection Elbow with Bracket
- Made of solid brass
- High-quality chrome finish
- Bracket angle is fixed
- Cover Ø 5.7cm
- Backflow protection according to DIN EN 1717
- 1/2" external thread
- Compatible with all standard shower hoses 1/2"
Hand Shower
- Made of solid brass
- High-quality chrome finish
- Function: Water flows when the button is pressed
Shower Hose
- Kink-resistant, durable, flexible stainless steel hose
- Brass cone and hex nut, high-quality chrome plated
- Cone with rubber protection
- Length 120 cm
- 1/2" thread
Shipping
- Shipping weight: 1.97 Kg
- Shipping method: Paket
Product Safety Regulation
Manufacturer information:
Name des Herstellers: PaulGurkes GmbH
Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland
Elektronische Adresse: anfrage@paulgurkesshop.de
Letztes Update: 19.05.2026, 19:45:16
Installation Instructions
| |||||||||
System Overview & Operation
| |||||||||
Drinking Water Protection & Safeguarding
| |||||||||
Structural Recommendation: Floor Drain
| |||||||||
Obligations of the Installer
| |||||||||
Disclaimer
| |||||||||
Contact Information
| |||||||||
[PDF] Allgemeine Pflegehinweise
PaulGurkes Concealed Bidet Set with WC Shower Hygienic Spray
Installation Instructions
| |||||||||
System Overview & Operation
| |||||||||
Drinking Water Protection & Safeguarding
| |||||||||
Structural Recommendation: Floor Drain
| |||||||||
Obligations of the Installer
| |||||||||
Disclaimer
| |||||||||
Contact Information
| |||||||||
Documents of the products included in the set
PGB1423x
Analysis Report Header
| |||||||||
Element Composition Table
| |||||||||
Compliance Statements
| |||||||||
Material Designation
| |||||||||
Footer Information
| |||||||||
| Analysis Report | |
| Description | The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus established. The tested material complies with the requirements of the German Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the German Federal Environment Agency, the material meets the standard DIN 50930-6, which describes corrosion resistance. |
| Material and Identification | |
| Material: | CC757S (CuZn39Pb1Al-C) |
| Report Number: | #2018-916 |
| Manufacturer Number: | PGB1423x |
| EAN: | 4250914801491 |
| Measurement Details | |
| Analysis Report: | XL2-99147 |
| Measurement Number: | 916 |
| Mode: | Alloys |
| Measurement Duration: | 8.0s |
| Time: | 08.10.2018 14:42:06 |
| Manufacturer Number: | pgb1423x |
| Material Suggestion: | CC575S_CuZn39Pb1Al |
| Element Analysis | |
| Element | % |
| ± 2σ | Min | Max |
| Copper (Cu) | 59.518 ± 0.638 | 58.000–63.000 |
| Zinc (Zn) | 38.881 ± 0.560 | 33.500–41.500 |
| Lead (Pb) | 1.332 ± 0.168 | 0.200–1.400 |
| Tin (Sn) | 0.144 ± 0.084 | 0.000–0.500 |
| Iron (Fe) | 0.089 ± 0.045 | 0.000–0.300 |
| Nickel (Ni) | 0.000 ± 0.070 | 0.000–0.200 |
| Manganese (Mn) | 0.000 ± 0.047 | 0.000–0.050 |
| Silicon (Si) | Max: 0.050 |
| Aluminum (Al) | 0.300–0.900 |
| Signatories and Contact | |
| Managing Director: | Olaf Manusch |
| Technical and Quality Management: | Marc Manusch |
| Address: | Klingenbergstr. 12, 31139 Hildesheim |
| Date and Location: | Hildesheim, Monday, October 8, 2018 |
| User Login: | Marc Manusch |
PGHPWAB002
Analysis Report
| |||||||||||||||
Probe Information
| |||||||||||||||
Report Details
| |||||||||||||||
Material Composition
| |||||||||||||||
Suitability for Drinking Water Installations
| |||||||||||||||
Material Compliance
| |||||||||||||||
Material Designation
| |||||||||||||||
Signatures
| |||||||||||||||
Date and Location
| |||||||||||||||
Source Information
| |||||||||||||||
| Manufacturer Information | |
| Manufacturer | PaulGurkes GmbH |
| Address | Klingenbergstr. 12 |
| City and Postal Code | 31139 Hildesheim |
| Analysis Report | |
| Analysis Report | XL2-99147 |
| Measurement No. | 693 |
| Mode | Alloys |
| Measurement Duration | 6.9s |
| Time | 29.09.2017 17:42:17 |
| Manufacturer Number | pghpwab002 - body |
| User Login | Marc Manusch |
| Material Suggestion | CW617N_CuZn40Pb2 |
| Element Analysis | |
| Element | % | ± | 2σ | Min | Max |
| Copper Cu | 57.999 | ± | 0.680 | 57.000 | 60.000 |
| Zinc Zn | 39.275 | ± | 0.605 | 37.000 | 41.500 |
| Lead Pb | 2.270 | ± | 0.225 | 1.600 | 2.200 |
| Iron Fe | 0.238 | ± | 0.066 | 0.000 | 0.300 |
| Tin Sn | 0.127 | ± | 0.098 | 0.000 | 0.300 |
| Nickel Ni | 0.076 | ± | 0.049 | 0.000 | 0.100 |
| Aluminum Al | 0.000 | | | | 0.050 |
| Analysis Report | |
| The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is hereby provided. | The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is hereby provided. |
| The tested material complies with the requirements of the Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. | The tested material complies with the requirements of the Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. |
| According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which sets out statements regarding corrosion resistance. | According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which sets out statements regarding corrosion resistance. |
| Material | |
| CW617N (CuZn40Pb2) | CW617N (CuZn40Pb2) |
| Report and Identification Numbers | |
| Report No.: #2017-693 | Report No.: #2017-693 |
| Manufacturer No.: PGHPWAB002 | Manufacturer No.: PGHPWAB002 |
| EAN: 4250914808674 | EAN: 4250914808674 |
| Analysis Report: XL2-99147 | Analysis Report: XL2-99147 |
| Measurement No.: 693 | Measurement No.: 693 |
| Measurement Results | |
| Element | % | ± 2σ | Min | Max |
| Copper Cu | 57,999 | ± 0,680 | 57,000 | 60,000 |
| Zinc Zn | 39,275 | ± 0,605 | 37,000 | 41,500 |
| Lead Pb | 2,270 | ± 0,225 | 1,600 | 2,200 |
| Iron Fe | 0,238 | ± 0,066 | 0,000 | 0,300 |
| Tin Sn | 0,127 | ± 0,098 | 0,000 | 0,300 |
| Nickel Ni | 0,076 | ± 0,049 | 0,000 | 0,100 |
| Aluminum Al | 0,000 | | | 0,050 |
| Measurement Information | |
| Mode: Alloys | Mode: Alloys |
| Measurement Time: 6.9 s | Measurement Time: 6.9 s |
| Time: 29.09.2017 17:42:17 | Time: 29.09.2017 17:42:17 |
| Material Suggestion: CW617N_CuZn40Pb2 | Material Suggestion: CW617N_CuZn40Pb2 |
| User Login: Marc Manusch | User Login: Marc Manusch |
| Company Information | |
| PaulGurkes GmbH | PaulGurkes GmbH |
| Klingenbergstr. 12 | Klingenbergstr. 12 |
| 31139 Hildesheim | 31139 Hildesheim |
| Approvals and Date | |
| Managing Director: Olaf Manusch | Managing Director: Olaf Manusch |
| Head of Engineering & Quality Management: Marc Manusch | Head of Engineering & Quality Management: Marc Manusch |
| Date: Hildesheim, Monday, April 3, 2017 | Date: Hildesheim, Monday, April 3, 2017 |
[PDF] Allgemeine Pflegehinweise
| Colour: | Chrome |
|---|
Login
8 reviews
The cartridge is not particularly durable - we (and acquaintances too) had to replace it after just under two years, after the original cartridge caused water damage due to leakage.