PaulGurkes Concealed Bidet Mixer with Oval Hand Shower
Prices excl. VAT plus shipping costs
No longer available
Note
- Protect the supply lines against backflow using an appropriate safety device.
Mixer
- Made of solid brass
- Chrome-plated
- Durable ceramic cartridge from SEDAL
- Oval design
- 1/2" thread
- 1 outlet
Note
This item features an integrated base body and is delivered ready for installation; no additional components are required.
Hand Shower
- Made of high-quality plastic, chrome-plated
- Length 11 cm
- Function: Water flows only when the button is pressed
- Do not leave under constant pressure
Wall Connection with Holder
- Made of solid brass
- High-quality chrome finish
- Holder angle is fixed
- Cover Ø 5.7 cm
- Backflow protection according to DIN EN 1717
- 1/2" external thread
- Compatible with all standard shower hoses 1/2"
Shower Hose
- Kink-resistant, durable, flexible stainless steel hose
- Brass cone and hex nut, high-quality chrome-plated
- Cone with rubber protection
- Length 120 cm
- 1/2" thread
Shipping
- Shipping weight: 2.06 Kg
- Shipping method: Paket
Product Safety Regulation
Manufacturer information:
Name des Herstellers: PaulGurkes GmbH
Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland
Elektronische Adresse: anfrage@paulgurkesshop.de
Letztes Update: 08.04.2026, 18:42:45
Installation Instructions
| |||||||||
System Overview & Operation
| |||||||||
Drinking Water Protection & Safeguarding
| |||||||||
Structural Recommendation: Floor Drain
| |||||||||
Obligations of the Installer
| |||||||||
Disclaimer
| |||||||||
Contact Information
| |||||||||
[PDF] Allgemeine Pflegehinweise
Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.
Weitere Kundenbilder zu im Set enthaltenen Produkten
PaulGurkes Concealed Bidet Mixer with Oval Hand Shower
Installation Instructions
| |||||||||
System Overview & Operation
| |||||||||
Drinking Water Protection & Safeguarding
| |||||||||
Structural Recommendation: Floor Drain
| |||||||||
Obligations of the Installer
| |||||||||
Disclaimer
| |||||||||
Contact Information
| |||||||||
Documents of the products included in the set
PGFA34K
Analysis Report Header
| |||||||||||
Element Composition
| |||||||||||
Compliance Statements
| |||||||||||
Material Designation and Signatures
| |||||||||||
| Analysis Report | |
| Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. | The sample was tested using X-ray fluorescence analysis and yielded the following measurement result. The proof of suitability for drinking water installations according to the Drinking Water Regulation (TrinkwV 2001) is thus established. The tested material complies with the requirements of the German Federal Environment Agency regarding "Evaluation criteria for metallic materials in contact with drinking water" - UBA positive list. The material complies with standard DIN 50930-6 according to the German Federal Environment Agency, which specifies information regarding corrosion resistance. |
| Material Data | |
| Werkstoff: CC575S (CuZn39Pb1Al) | Material: CC575S (CuZn39Pb1Al) |
| Bericht-Nr.: #2017-64 | Report No.: #2017-64 |
| Herstellernummer: PGFA34K | Manufacturer Number: PGFA34K |
| EAN: 4250914801361 | EAN: 4250914801361 |
| Klingenbergstr. 12 31139 Hildesheim | Klingenbergstr. 12 31139 Hildesheim |
| Measurement Data | |
| Analysenbericht XL2-99147 | Analysis Report XL2-99147 |
| Messung Nr.: 64 | Measurement No.: 64 |
| Modus: Legierungen | Mode: Alloys |
| Messdauer: 11,6s | Measurement Duration: 11.6s |
| Zeit: 10.03.2017 10:05:10 | Time: 10.03.2017 10:05:10 |
| Herstellernummer PGFA34K | Manufacturer Number PGFA34K |
| User Login Marc Manusch | User Login Marc Manusch |
| Werkstoffvorschlag: CC575S_CuZn39Pb1Al | Material Suggestion: CC575S_CuZn39Pb1Al |
| Element Analysis | |
| Kupfer Cu: 61,375 ± 0,486 % (Min: 58,000 - Max: 63,000) | Copper Cu: 61.375 ± 0.486 % (Min: 58.000 - Max: 63.000) |
| Zink Zn: 37,707 ± 0,425 % (Min: 33,500 - Max: 41,500) | Zinc Zn: 37.707 ± 0.425 % (Min: 33.500 - Max: 41.500) |
| Bismut Bi: 0,591 ± 0,098 % | Bismuth Bi: 0.591 ± 0.098 % |
| Blei Pb: 0,234 ± 0,070 % (Min: 0,200 - Max: 1,400) | Lead Pb: 0.234 ± 0.070 % (Min: 0.200 - Max: 1.400) |
| Eisen Fe: 0,081 ± 0,034 % (Min: 0,000 - Max: 0,300) | Iron Fe: 0.081 ± 0.034 % (Min: 0.000 - Max: 0.300) |
| Zinn Sn: 0,000 % (Min: 0,000 - Max: 0,500) | Tin Sn: 0.000 % (Min: 0.000 - Max: 0.500) |
| Aluminium Al: 0,300 % (Min: 0,000 - Max: 0,900) | Aluminium Al: 0.300 % (Min: 0.000 - Max: 0.900) |
| Nickel Ni: 0,000 % (Min: 0,000 - Max: 0,200) | Nickel Ni: 0.000 % (Min: 0.000 - Max: 0.200) |
| Mangan Mn: 0,000 % (Min: 0,000 - Max: 0,050) | Manganese Mn: 0.000 % (Min: 0.000 - Max: 0.050) |
| Silizium Si: 0,000 % (Min: 0,000 - Max: 0,050) | Silicon Si: 0.000 % (Min: 0.000 - Max: 0.050) |
| Signatures and Date | |
| Hildesheim, Montag, 3. April 2017 | Hildesheim, Monday, April 3, 2017 |
| Marc Manusch - Leitung Technik & Qualitätswesen | Marc Manusch - Head of Technology & Quality Management |
| Olaf Manusch - Geschäftsführer | Olaf Manusch - Managing Director |
| References | |
| Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser", (abgerufen am 03.04.2017). | German Federal Environment Agency: "Evaluation Criteria for Metallic Materials in Contact with Drinking Water", (accessed April 3, 2017). |
PGHPWAB002
Analysis Report
| |||||||||||||||
Probe Information
| |||||||||||||||
Report Details
| |||||||||||||||
Material Composition
| |||||||||||||||
Suitability for Drinking Water Installations
| |||||||||||||||
Material Compliance
| |||||||||||||||
Material Designation
| |||||||||||||||
Signatures
| |||||||||||||||
Date and Location
| |||||||||||||||
Source Information
| |||||||||||||||
| Manufacturer Information | |
| Manufacturer | PaulGurkes GmbH |
| Address | Klingenbergstr. 12 |
| City and Postal Code | 31139 Hildesheim |
| Analysis Report | |
| Analysis Report | XL2-99147 |
| Measurement No. | 693 |
| Mode | Alloys |
| Measurement Duration | 6.9s |
| Time | 29.09.2017 17:42:17 |
| Manufacturer Number | pghpwab002 - body |
| User Login | Marc Manusch |
| Material Suggestion | CW617N_CuZn40Pb2 |
| Element Analysis | |
| Element | % | ± | 2σ | Min | Max |
| Copper Cu | 57.999 | ± | 0.680 | 57.000 | 60.000 |
| Zinc Zn | 39.275 | ± | 0.605 | 37.000 | 41.500 |
| Lead Pb | 2.270 | ± | 0.225 | 1.600 | 2.200 |
| Iron Fe | 0.238 | ± | 0.066 | 0.000 | 0.300 |
| Tin Sn | 0.127 | ± | 0.098 | 0.000 | 0.300 |
| Nickel Ni | 0.076 | ± | 0.049 | 0.000 | 0.100 |
| Aluminum Al | 0.000 | | | | 0.050 |
| Analysis Report | |
| The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is hereby provided. | The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is hereby provided. |
| The tested material complies with the requirements of the Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. | The tested material complies with the requirements of the Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. |
| According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which sets out statements regarding corrosion resistance. | According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which sets out statements regarding corrosion resistance. |
| Material | |
| CW617N (CuZn40Pb2) | CW617N (CuZn40Pb2) |
| Report and Identification Numbers | |
| Report No.: #2017-693 | Report No.: #2017-693 |
| Manufacturer No.: PGHPWAB002 | Manufacturer No.: PGHPWAB002 |
| EAN: 4250914808674 | EAN: 4250914808674 |
| Analysis Report: XL2-99147 | Analysis Report: XL2-99147 |
| Measurement No.: 693 | Measurement No.: 693 |
| Measurement Results | |
| Element | % | ± 2σ | Min | Max |
| Copper Cu | 57,999 | ± 0,680 | 57,000 | 60,000 |
| Zinc Zn | 39,275 | ± 0,605 | 37,000 | 41,500 |
| Lead Pb | 2,270 | ± 0,225 | 1,600 | 2,200 |
| Iron Fe | 0,238 | ± 0,066 | 0,000 | 0,300 |
| Tin Sn | 0,127 | ± 0,098 | 0,000 | 0,300 |
| Nickel Ni | 0,076 | ± 0,049 | 0,000 | 0,100 |
| Aluminum Al | 0,000 | | | 0,050 |
| Measurement Information | |
| Mode: Alloys | Mode: Alloys |
| Measurement Time: 6.9 s | Measurement Time: 6.9 s |
| Time: 29.09.2017 17:42:17 | Time: 29.09.2017 17:42:17 |
| Material Suggestion: CW617N_CuZn40Pb2 | Material Suggestion: CW617N_CuZn40Pb2 |
| User Login: Marc Manusch | User Login: Marc Manusch |
| Company Information | |
| PaulGurkes GmbH | PaulGurkes GmbH |
| Klingenbergstr. 12 | Klingenbergstr. 12 |
| 31139 Hildesheim | 31139 Hildesheim |
| Approvals and Date | |
| Managing Director: Olaf Manusch | Managing Director: Olaf Manusch |
| Head of Engineering & Quality Management: Marc Manusch | Head of Engineering & Quality Management: Marc Manusch |
| Date: Hildesheim, Monday, April 3, 2017 | Date: Hildesheim, Monday, April 3, 2017 |
[PDF] Allgemeine Pflegehinweise
| Colour: | Chrome |
|---|