Skip to main content Skip to search Skip to main navigation
Please note our information regarding customs and duties. Delivery available from £140.
Average rating with

Average rating of 4.9 out of 5 stars

(4.91/5.00) calculated out of 2927 reviews

Concealed Body

  • Compatible with faucets from PaulGurkes for PGBASIC
  • Made of solid brass
  • 4-Way / 3-Way / 2-Way / 1-Way
  • Integrated level for easy installation
  • Includes sealing sleeve for secure fitting

Installation Instructions

Connect the consumers according to the following guidelines:

2-Way Faucet:

  • Top outlet: Bathtub inlet
  • Bottom outlet: Hand shower

By connecting according to these guidelines, you can easily use a different faucet.

Action Select Faucet 2-Consumer

  • Required base body PGBASIC
  • Faucet made of solid brass
  • For two consumers
  • Symbol set (hand shower, overhead shower, bathtub inlet, waterfall)
  • Trim and temperature control made of metal
  • Vibration dampener for noise reduction

Operation

  • Pressing the buttons switches the outlets
  • The outlets can be connected in parallel, allowing multiple consumers to be controlled together
  • Temperature control by turning the knob
  • Water flow regulation is not possible with all "PUSH/SELECT" faucets

Bathtub Inlet

  • Designer bathtub inlet
  • Made of solid brass
  • Chrome-plated
  • Spout inlet
  • Plastic grid
  • Projection 13 cm
  • Outlet 2 x 5 cm
  • Trim 5.5 x 7.5 x 1 cm
  • 1/2" thread

Hand Shower

  • Square handheld shower
  • 1 function
  • Made of plastic
  • High-quality chrome finish
  • 50 anti-limescale nozzles
  • Length 20 cm (with thread 21 cm)
  • 2 x 3.8 cm
  • 1/2" thread

Wall Connection Elbow

  • Square design
  • Made of solid brass
  • High-quality chrome plating
  • Backflow prevention according to DIN EN 1717
  • 1/2" internal thread for wall
  • 1/2" external thread for shower
  • Fits all standard shower hoses 1/2"

Shower Holder

  • Square design
  • Made of plastic
  • High-quality chrome finish
  • Adjustable angle of the holder
  • Compatible with all handheld showers

Length 120 cm

  • The double-sided 1/2" swivel cones prevent twisting of the hose.
  • Made of stainless steel, polished to a high shine
  • Double winding (overlapping) for high tensile strength
  • Kink-resistant, durable, flexible
  • Swivel cones made of solid brass, high-quality chrome finish
  • Certified: KTW recommendation, EN 1113, NF077
  • Made in Germany

Shipping

  • Shipping weight: 6.25 Kg
  • Shipping method: Paket

Product Safety Regulation

Manufacturer information:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 08.04.2026, 18:44:30

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Weitere Kundenbilder zu im Set enthaltenen Produkten

PaulGurkes Concealed Body for Faucets up to 4-Way

PGBASIC

£74*

PaulGurkes Action Shower Select Faucet 2-Way Concealed for Base Body PGBASIC

PGACTION2

£162*

PaulGurkes Rectangular Waterfall Bath Spout

PG5E

£51*

PaulGurkes Square Flat Hand Shower - Rectangular Shower Head

PG1329

£13*

PaulGurkes Corner Wall Connector

PG8M

£22*

PaulGurkes Square Shower Holder Adjustable Angle Chrome

PGSH

£11*

PaulGurkes Stainless Steel Shower Hose 120cm with Swivel Ends

PGdoubleAgraff120

£15*

Documents of the products included in the set

PGBASIC

[pdf] PGBASIC-v1.2
Components
Nr. Komponente Anzahl 1 Wasserwaage 2 2 Pappkarte 1 3 Wasserwaagenrahmen 1 4 Schraube 6 5 Spülvorrichtung 1 6 Dichtung für Spülvorrichtung 1 7 Pin 2 8 Dichtmanschette 1 9 Grundkörper 1 10 Spreizbolzen 4 11 Innensechskantschlüssel 1 12 Verschlussstopfen 3 13 Montageanleitung 1 Zertifikat & Videoanleitung unter: 14 1 www.PaulGurkesShop.deNo. Component Quantity 1 Spirit level 2 2 Cardboard 1 3 Spirit level frame 1 4 Screw 6 5 Flushing device 1 6 Seal for flushing device 1 7 Pin 2 8 Sealing sleeve 1 9 Main body 1 10 Expansion bolt 4 11 Allen key 1 12 Sealing plugs 3 13 Installation instructions 1 Certificate & Video instructions under: 14 1 www.PaulGurkesShop.de
Installation Preparation
Installationsvorbereitung • Für die Installation der Box wird ein Loch von mindestens 200mm x 220mm benötigt. • Die Einbautiefe beträgt 83mm - 108mm. • Bereiten Sie die Leitungen wie in der folgenden Abbildung vor. • Der Druck sollte 0,5 - 10 Bar nicht überschreiten. Empfohlener Druck ist 5 Bar.Installation preparation • A hole of at least 200mm x 220mm is required to install the box. • The installation depth is 83mm - 108mm. • Prepare the pipes as shown in the following illustration. • The pressure should not exceed 0.5 - 10 bar. Recommended pressure is 5 bar.
Installation Step 1 - Preparation
1. Installationsschritt - Vorbereitung • Merke: Die Box ist standardmäßig für vier Ausgänge konfiguriert. Für eine Nutzung von einem / zwei oder drei Ausgängen blockieren Sie die Ausgänge wie im unteren Schaubild abgebildet. • Bohren Sie die Installationslöcher, wie in der Abbildung zu sehen ist. • Platzieren Sie nun die Box in dem Installationsloch und fixieren Sie diese mit den Spreizschrauben. • Für die Installation in eine Ständerwand montieren Sie die Box wie im oberen Schaubild. • Überprüfen Sie die Festigkeit der Schrauben. • Schließen Sie die Warmwasser und Kaltwasser Leitungen an. • Schließen Sie die Verbraucher nach dem unteren Schaubild an.1. Installation step - Preparation • Note: The box is configured by default for four outputs. For use with one / two or three outputs, block the outputs as shown in the diagram below. • Drill the installation holes as shown in the illustration. • Now place the box in the installation hole and fix it with the expansion bolts. • For installation in a stud wall, mount the box as shown in the diagram above. • Check the tightness of the screws. • Connect the hot and cold water pipes. • Connect the consumers according to the diagram below.
Installation Step 2 - Function Overview
2. Installationsschritt - Funktionsübersicht2. Installation step - Function overview
Important Notes
WICHTIG! • Der untere Ausgang wird zuerst angesteuert (bei 2-Wege Armaturen). • Überprüfen Sie die Richtigkeit der Ausgänge an den Verbrauchern vor dem Verputzen in Abhängigkeit der zur Verwendung geplanten Armatur!IMPORTANT! • The lower outlet is activated first (for 2-way fittings). • Check that the outlets are correctly connected to the consumers before plastering, depending on the fitting planned for use!
Installation Step 2 - Testing
2. Installationsschritt - Testen • Öffnen Sie die Wasserleitungen und prüfen Sie die Montage auf Dichtheit. • Demontieren Sie die Spülvorrichtung und entfernen Sie die Gummistopfen aus dem Grundkörper. • Montieren Sie die Verschlusskappe erneut und spülen Sie 3 Minuten die Leitungen, um diese von Verschmutzungen zu säubern.2. Installation step - Testing • Open the water pipes and check the installation for leaks. • Disassemble the flushing device and remove the rubber plugs from the main body. • Reassemble the sealing cap and flush the pipes for 3 minutes to clean them of dirt.
Installation Step 3 - Plastering
3. Installationsschritt - Verputzen • Wenn die Installation die Dichtheitsprüfung bestanden hat, verputzen Sie die Montage. • Kontrollieren Sie die Position der Box. • Dichten Sie nun die Box im Verbund ab, bevor Sie die Fließen an die Wand bringen. • Verfliesen Sie die Installation. • Schneiden Sie das überstehende Material der Box ab. • Dichten Sie zuletzt die Schnittkante ab. • Die Installation ist abgeschlossen. Montieren Sie nun die Armatur.3. Installation step - Plastering • Once the installation has passed the leak test, plaster the installation. • Check the position of the box. • Now seal the box in the composite before attaching the tiles to the wall. • Tile the installation. • Cut off any protruding material from the box. • Finally, seal the cut edge. • The installation is complete. Now install the fitting.
Important Legal Information
WICHTIG! • Beachten Sie bei der Installation alle erforderlichen gesetzlichen und nationalen Bestimmungen (anerkannte Regeln der Technik) und halten Sie diese ein.IMPORTANT! • During installation, observe and comply with all necessary legal and national regulations (recognized rules of technology).
[pdf] PGBASIC-Anschlussplan-v1.0
Anschlussplan für PGBASICConnection diagram for PGBASIC
MontagehinweiseInstallation instructions
HinweiseNotes
Beachten Sie bei der Montage unbedingt die beiliegenden Installationsanleitungen.When installing, be sure to observe the enclosed installation instructions.
Prüfen Sie die Montage unbedingt vor dem Fliesenlegen auf Korrektheit der Verbraucher!Check the installation before tiling to ensure the consumer unit is correct!
Prüfen Sie die Montage des Grundkörpers in Hinsicht auf die zur Verwendung geplanten Komponenten.Check the installation of the base unit with regard to the components planned for use.
Duschsystem 2-Wege2-way shower system
Duschsystem 3-Wege3-way shower system
Wasserfall DuschsystemWaterfall shower system
Wannenset 2-Wege2-way tub set
Duschsystem 4-Wege4-way shower system
WanneneinlaufTub inlet
RegenduscheRain shower
HandbrauseHand shower
RegenfallRainfall
geblocktblocked
WasserfallWaterfall
Verbraucher 4Consumer 4
[pdf] PGBASIC-Durchflussmengen
Flow rates for PGBASIC
Durchflussmengen für PGBASICFlow rates for PGBASIC
Durchflussmengen in l/minFlow rates in l/min
Single-lever mixer (2-way)
Einhandmischer (2-Wege)Single-lever mixer (2-way)
AusgangOutlet
Warm Gemisch KaltWarm Mixed Cold
B 9,5 10,3 8,8B 9.5 10.3 8.8
D 9,6 10,6 8,9D 9.6 10.6 8.9
B 16,7 18,3 15,4B 16.7 18.3 15.4
D 17 18,7 15,7D 17 18.7 15.7
Thermostatic valves (2-way + 3-way)
Thermostatarmaturen (2-Wege + 3-Wege)Thermostatic valves (2-way + 3-way)
AusgangOutlet
Warm Gemisch KaltWarm Mixed Cold
B 8 12,2 9,3B 8 12.2 9.3
C 8 12 9,2C 8 12 9.2
D 7,8 12,5 9D 7.8 12.5 9
B 14,2 22,3 16,5B 14.2 22.3 16.5
C 14 21,8 16,3C 14 21.8 16.3
D 14,6 22,5 16,6D 14.6 22.5 16.6
Select valves (2-way + 3-way)
Selectarmaturen (2-Wege + 3-Wege)Select valves (2-way + 3-way)
AusgangOutlet
Warm Gemisch KaltWarm Mixed Cold
B 14,6 17,4 14,6B 14.6 17.4 14.6
C 16,5 20,2 16,9C 16.5 20.2 16.9
D 15,6 18,6 15,9D 15.6 18.6 15.9
Single-lever mixer (4-way)
Einhandmischer (4-Wege)Single-lever mixer (4-way)
AusgangOutlet
Warm Gemisch KaltWarm Mixed Cold
A 9,3 10,3 9,8A 9.3 10.3 9.8
B 9,2 10,2 9,7B 9.2 10.2 9.7
C 9,4 10,4 9,8C 9.4 10.4 9.8
D 9,7 10,7 10D 9.7 10.7 10
A 16,8 18,7 17,8A 16.8 18.7 17.8
B 16,6 18,5 17,6B 16.6 18.5 17.6
C 16,8 18,7 17,8C 16.8 18.7 17.8
D 17,3 19,5 18,3D 17.3 19.5 18.3
[pdf] Analysebericht-PGBASIC
Analysis Report
AnalyseberichtAnalysis Report
Introduction
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested by X-ray fluorescence analysis and yielded the following measurement result.
Report Information
Bericht-Nr.: #2017-749Report No.: #2017-749
Herstellernummer: PGBASICManufacturer Number: PGBASIC
Material Composition
Kupfer Cu 58,679 ± 0,573 57,000 60,000Copper Cu 58.679 ± 0.573 57.000 60.000
Zink Zn 39,262 ± 0,512 37,000 41,500Zinc Zn 39.262 ± 0.512 37.000 41.500
Blei Pb 1,727 ± 0,173 1,600 2,200Lead Pb 1.727 ± 0.173 1.600 2.200
Eisen Fe 0,153 ± 0,049 0,000 0,300Iron Fe 0.153 ± 0.049 0.000 0.300
Zinn Sn 0,114 ± 0,074 0,000 0,300Tin Sn 0.114 ± 0.074 0.000 0.300
Nickel Ni 0,064 ± 0,041 0,000 0,100Nickel Ni 0.064 ± 0.041 0.000 0.100
Aluminium Al 0,000 0,050Aluminum Al 0.000 0.050
Suitability for Drinking Water
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.Proof of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been provided.
Material Compliance
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency regarding the "Assessment principles for metallic materials in contact with drinking water"- UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information regarding corrosion resistance.
Material Designation
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Footer
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).German Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 03.04.2017).
[pdf] PGBASIC_Anordnungsplan
Components List
Mixed
Product Manuals - PGBASIC - Version 1
Connection Diagram for PGBASIC
Connection Diagram for PGBASIC v1.0 of 1
Installation Instructions
Installation Instructions Be sure to follow the included installation instructions during assembly.
Check the assembly carefully before tiling to ensure correct placement of the consumers!
Check the assembly of the basic body with regard to the components planned for use.
Notes
Notes Hand shower blocked blocked
Rain shower hand shower blocked
Rain shower bathtub inlet hand shower blocked blocked
Bathtub inlet rain waterfall hand shower blocked
Shower system 3-way
Shower system 2-way bathtub set 2-way waterfall
Shower system shower system 4-way hand shower rain shower bathtub inlet consumer 4
Product Manuals - PGBASIC - Version 1.2
Analysis Reports - PGBASIC - Version 1
Product Information
Produktname: PaulGurkes Unterputz Grundkörper für Armaturen bis 4-Wege Product Name: PaulGurkes In-Wall Rough-In Body for Fixtures up to 4-Way
Artikelnummer: PGBASIC Article Number: PGBASIC
Version: v1.2 Version: v1.2
Components
1 - Wasserwaage - 2 1 - Spirit Level - 2
2 - Pappkarte - 1 2 - Cardboard Card - 1
3 - Wasserwaagenrahmen - 1 3 - Spirit Level Frame - 1
4 - Schraube - 6 4 - Screw - 6
5 - Spülvorrichtung - 1 5 - Flush Device - 1
6 - Dichtung für Spülvorrichtung - 1 6 - Seal for Flush Device - 1
7 - Pin - 2 7 - Pin - 2
8 - Dichtmanschette - 1 8 - Sealing Cuff - 1
9 - Grundkörper - 1 9 - Rough-In Body - 1
10 - Spreizbolzen - 4 10 - Expansion Bolt - 4
11 - Innensechskantschlüssel - 1 11 - Hex Key - 1
12 - Verschlussstopfen - 3 12 - Closure Plug - 3
13 - Montageanleitung - 1 13 - Assembly Instructions - 1
14 - Zertifikat & Videoanleitung unter: www.PaulGurkesShop.de 14 - Certificate & Video Instructions at: www.PaulGurkesShop.de
Installation Preparation
Für die Installation der Box wird ein Loch von mindestens 200mm x 220mm benötigt. A hole of at least 200 mm x 220 mm is required for box installation.
Die Einbautiefe beträgt 83mm - 108mm. Installation depth is 83 mm - 108 mm.
Bereiten Sie die Leitungen wie in der folgenden Abbildung vor. Prepare the lines as shown in the following figure.
Der Druck sollte 0,5 - 10 Bar nicht überschreiten. Empfohlener Druck ist 5 Bar. Pressure should not exceed 0.5 - 10 bar. Recommended pressure is 5 bar.
Step 1 of Installation - Preparation
Die Box ist standardmäßig für vier Ausgänge konfiguriert. Für eine Nutzung von einem / zwei oder drei Ausgängen blockieren Sie die Ausgänge wie im unteren Schaubild abgebildet. The box is configured by default for four outlets. For use of one, two, or three outlets, block the outlets as shown in the diagram below.
Bohren Sie die Installationslöcher, wie in der Abbildung zu sehen ist. Drill the installation holes as shown in the illustration.
Platzieren Sie nun die Box in dem Installationsloch und fixieren Sie diese mit den Spreizschrauben. Now place the box in the installation hole and secure it with the expansion bolts.
Für die Installation in eine Ständerwand montieren Sie die Box wie im oberen Schaubild. For installation in a stud wall, mount the box as shown in the upper diagram.
Überprüfen Sie die Festigkeit der Schrauben. Check the tightness of the screws.
Analysis Report
Analysebericht The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The suitability of the product for use in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus proven. The tested material meets the requirements of the German Federal Environment Agency (UBA) concerning "Assessment bases for metallic materials in contact with drinking water" – UBA positive list. The material complies with DIN 50930-6 standard according to the German Federal Environment Agency, which provides statements regarding corrosion resistance.
Material and Designation
Material: CW617N (CuZn40Pb2)
Manufacturer Number: PGBASIC
EAN: 4250914808827
Report No.: #2017-749
Measurement Results
Analysis Report: XL2-99147
Measurement No.: 749
Mode: Alloys
Measurement Duration: 8.6s
Time: 02.12.2017 11:48:23
Manufacturer Number: pgbasic
Material Suggestion: CW617N_CuZn40Pb2
Element Analysis
Element % ± 2σ Min Max
Copper Cu 58.679 ± 0.573 57.000 60.000
Zinc Zn 39.262 ± 0.512 37.000 41.500
Lead Pb 1.727 ± 0.173 1.600 2.200
Iron Fe 0.153 ± 0.049 0.000 0.300
Tin Sn 0.114 ± 0.074 0.000 0.300
Nickel Ni 0.064 ± 0.041 0.000 0.100
Aluminum Al 0.000 0.050
Signatory and Contact
Signatory: Olaf Manusch, Managing Director
Engineering and Quality Management: Marc Manusch, Engineering and Quality Management
Company: PaulGurkes GmbH, Klingenbergstr. 12, 31139 Hildesheim
User Login: Marc Manusch
Date: Hildesheim, December 2, 2017
Layout Plans - PGBASIC - Version 1
Components
1 8PM4X16 1 8PM4X16
2 81BE0000 2 81BE0000
3 80BE0000 3 80BE0000
4 8J128X18A 4 8J128X18A
5 81T23187 5 81T23187
6 85BK001 6 85BK001
7 82BE0000 7 82BE0000
8 8J103X16A 8 8J103X16A
9 8XJBE001 9 8XJBE001
10 84BE0000 10 84BE0000
11 8PM5X12 11 8PM5X12
12 85BE0000 12 85BE0000
13 103BE000 13 103BE000
14 88BM0000 14 88BM0000
15 8XJBE002 15 8XJBE002
16 83BE0000 16 83BE0000
17 8JT1A2D2 17 8JT1A2D2
18 8J22X24A 18 8J22X24A
19 8BS40X112 19 8BS40X112
20 8STG605 20 8STG605
Temperature Ranges
Max Mixed Cold Hot 108 Max Mixed Cold Hot 108
Min Mixed Mixed Mixed 80 Min Mixed Mixed Mixed 80
Manufacturer
PaulGurkes GmbH PaulGurkes GmbH
Miscellaneous Documents - PGBASIC - Version 1
Flow Rates for PGBASIC
v1.0 v1.0
Thermostatic Mixers (2-way + 3-way)
Bar Outlet Hot Water Mixed Cold Water
1 B 8 12,2 9,3
1 C 8 12 9,2
1 D 7,8 12,5 9
3 B 14,2 22,3 16,5
3 C 14 21,8 16,3
3 D 14,6 22,5 16,6
Single-Lever Mixer (2-way)
Bar Outlet Hot Water Mixed Cold Water
1 B 9,5 10,3 8,8
1 D 9,6 10,6 8,9
3 B 16,7 18,3 15,4
3 D 17 18,7 15,7
Select Mixers (2-way + 3-way)
Bar Outlet Hot Water Mixed Cold Water
3 B 14,6 17,4 14,6
3 C 16,5 20,2 16,9
3 D 15,6 18,6 15,9
Single-Lever Mixer (4-way)
Bar Outlet Hot Water Mixed Cold Water
1 A 9,3 10,3 9,8
1 B 9,2 10,2 9,7
1 C 9,4 10,4 9,8
1 D 9,7 10,7 10
3 A 16,8 18,7 17,8
3 B 16,6 18,5 17,6
3 C 16,8 18,7 17,8
3 D 17,3 19,5 18,3

PGACTION2

[pdf] Analysebericht-PGACTION
Analysis Report Header
AnalyseberichtAnalysis Report
Introduction
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Report Information
Bericht-Nr.: #2017-742Report No.: #2017-742
Herstellernummer: PGACTION2 / PGACTION3Manufacturer Number: PGACTION2 / PGACTION3
Element Composition
Kupfer Cu 60,708 ± 0,508 59,500 61,500Copper Cu 60.708 ± 0.508 59.500 61.500
Zink Zn 37,855 ± 0,437 36,000 40,000Zinc Zn 37.855 ± 0.437 36.000 40.000
Blei Pb 1,349 ± 0,132 0,800 2,000Lead Pb 1.349 ± 0.132 0.800 2.000
Eisen Fe 0,079 ± 0,034 0,000 0,200Iron Fe 0.079 ± 0.034 0.000 0.200
Zinn Sn 0,000 ± 0,090 0,000 0,200Tin Sn 0.000 ± 0.090 0.000 0.200
Nickel Ni 0,000 ± 0,053 0,000 0,300Nickel Ni 0.000 ± 0.053 0.000 0.300
Compliance Statement
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The evidence of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA-Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Environment Agency (Umweltbundesamt) regarding the "Assessment bases for metallic materials in contact with drinking water" - UBA positive list. According to the German Environment Agency, the material meets the DIN 50930-6 standard, which specifies statements regarding corrosion resistance.
Material Identification
Werkstoff: CC575S (CuZn39PblAl)Material: CC575S (CuZn39PblAl)
Footer and Signatures
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, 28. März 2018Hildesheim, March 28, 2018
Marc Manusch Leitung Technik & QualitätswesenMarc Manusch Head of Engineering & Quality Assurance
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).German Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 03.04.2017).
[pdf] PGACTION2_Anordnungsplan
Component List

PG5E

[pdf] PG5E-v1.0
Components
Nr. Komponente AnzahlNo. Component Quantity
1 Auslauf 11 Spout 1
2 Madenschraube 22 Grub screw 2
3 Madenschraube 13 Grub screw 1
4 Blende 14 Cover 1
Assembly
Montage • Montieren Sie den Artikel wie im unteren Schaubild.Assembly • Mount the article as shown in the picture below.
Cleaning & Maintenance
Säuberung & Wartung Um eine gleichbleibende Qualität zu gewährleisten, ist folgendes zu beachten: • Mit sauberem Wasser abspülen & mit einem Mikrofasertuch trocknen. • Schmutz nur mit milden Reinigungsmitteln entfernen. • Benutzen Sie keine Scheuermilch, Polierpaste, Papiertücher, etc. • Benutzen Sie keine säurehaltigen Reinigungsmittel oder Seife. Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.Cleaning & Maintenance To ensure consistent quality, please note the following: • Rinse with clean water and dry with a microfiber cloth. • Remove dirt only with mild detergents. • Do not use scouring milk, polishing paste, paper towels, etc. • Do not use acidic cleaning agents or soap. We reserve the right to make updates, changes or additions to the information and data provided.

PG8M

[pdf] PG8M-v1.1
Installation Note
Installationshinweis • Für die Montage benötigen Sie ein 1/2″ Gewindeadapter!Installation Note • For assembly, you need a 1/2″ thread adapter!
Installation
Installation • Stecken Sie die Blende über das 1/2" Gewinde in der Wand. • Drehen Sie den Grundkörper auf das Gewinde. Achten Sie dadrauf, dass Sie die Blende nicht zerkratzen. • Drehen Sie den Duschschlauch auf das vorgesehene Gewinde.Installation • Place the cover over the 1/2" thread in the wall. • Turn the main body onto the thread. Make sure you do not scratch the cover. • Turn the shower hose onto the provided thread.
Cleaning & Maintenance
Säuberung & Wartung Um eine gleichbleibende Qualität zu gewährleisten, ist folgendes zu beachten: • Mit sauberem Wasser abspülen & mit Mikrofasertuch trocknen. • Schmutz nur mit milden Reinigungsmitteln entfernen. • Benutzen Sie keine Scheuermilch, Polierpaste, Papiertücher, etc. • Benutzen Sie keine säurehaltigen Reinigungsmittel oder Seife.Cleaning & Maintenance To ensure consistent quality, observe the following: • Rinse with clean water & dry with a microfiber cloth. • Remove dirt only with mild detergents. • Do not use scouring milk, polishing paste, paper towels, etc. • Do not use acidic detergents or soap.
PaulGurkes Quality
PaulGurkes Qualität • Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt. • Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle. • Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns.PaulGurkes Quality • Congratulations on purchasing your PaulGurkes quality product. Our products are technically sophisticated and manufactured using high-quality materials. • Each product undergoes a hand-picked quality control. • If you are not satisfied with our products, please contact us.

[PDF] Allgemeine Pflegehinweise
Application: Cold and hot water supply
Application area: Bathtub
Colour: Chrome
Connection: High pressure – pressure-resistant
Connection type: Concealed installation unit (included in delivery)

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Loading...

Loading 3D model...

Mouse: Rotate | Scroll: Zoom | Right-click: Pan Finger: Rotate | Pinch: Zoom | Two fingers: Pan